Study on the repeatability of shear wave elastography in measuring cervical hardness
由同一名接受过SWE检测培训的高年资医师于同一天不同时间点,前后2次对100名处于育龄期但未育的健康女性宫颈行剪切波弹性成像,测量时选取宫颈4个位点:内口前唇(anterior lip of the inner mouth,IA)、内口后唇(posterior lip of the inner mouth,IP)、外口前唇(anterior lip of the outer mouth,EA)及外口后唇(posterior lip of the outer mouth,EP),获取育龄期健康未育女性宫颈杨氏模量值。使用组内相关系数(interclass correlation coefficient,ICC)评价检查者内可重复性,同时绘制Bland-Altman散点图评价测量一致性。
To assess the repeatability of shear wave elastography(SWE) in the measurement of cervical Young's modulus in healthy childless women of childbearing age.
Methods
2
SWE was performed twice on the cervix of 100 healthy childless women of childbearing age on the same day and at different time points by the same senior physician who had received SWE testing training. The cervical Young's modulus value in healthy childless women of childbearing age was obtained by measuring the following four sites of cervix:anterior lip of the inner mouth(IA),posterior lip of the inner mouth(IP),anterior lip of the outer mouth(EA) and posterior lip of the outer mouth(EP). Interclass correlation coefficient(ICC) was used to evaluate the intra-group repeatability,and Bland-Altman scatter plot was performed to assess the consistency of the measurement.
Results
2
There were no statistical significances between the two measurements of the four sites of cervix(
P
>
0.05). The intra -group correlation coefficients of Young's modulus at IA,EA and EP were 0.828,0.785 and 0.768 respectively,indicating quite satisfactory repeatability. The intra-group correlation coefficient of Young's modulus at IP was 0.632,indicating satisfactory repeatability. And Bland-Altman scatter plot indicated preferable intra-group consistency of Young's modulus measured by SWE at four sites of cervix.
Conclusion
2
SWE can be used to measure cervical hardness,and has good repeatability and consistency at different sites of cervix.
Yu YN , Chang JW , Mi YR , et al . Research overview of the evaluation of peripheral neuropathy by ultrasonic elastography [J ] . Chin J Med Guide , 2022 , 24 ( 3 ): 248 - 252 .
Schmalzl J , Fenwick A , Boehm D , et al . The application of ultrasound elastography in the shoulder [J ] . J Shoulder Elb Surg , 2017 , 26 ( 12 ): 2236 - 2246 .
Zhang JJ , Xu HF , Li TH , et al . Application value of acoustic radiation force impulse imaging combined with stress elastography in the diagnosis of hysteromyoma degeneration [J ] . J Clin Ultrasound Med , 2020 , 22 ( 11 ): 843 - 846 .
Huang DD , Chen LZ , Xing HY , et al . Repeatability of shear wave elastography on Median nerve [J ] . Chin J Med Imaging , 2018 , 26 ( 5 ): 383 - 387 .
Agarwal A , Agarwal S , Chandak S . Role of acoustic radiation force impulse and shear wave velocity in prediction of preterm birth:a prospective study [J ] . Acta Radiol , 2018 , 59 ( 6 ): 755 - 762 .
Ono T , Katsura D , Yamada K , et al . Use of ultrasound shear-wave elastography to evaluate change in cervical stiffness during pregnancy [J ] . J Obstet Gynaecol Res , 2017 , 43 ( 9 ): 1405 - 1410 .
Jansen C , Möller P , Meyer C , et al . Increase in liver stiffness after transjugular intrahepatic portosystemic shunt is associated with inflammation and predicts mortality [J ] . Hepatology , 2018 , 67 ( 4 ): 1472 - 1484 .
Li L , Xiong W , Chen Q , et al . Transvaginal cervical shear wave elastography for evaluating preterm birth [J ] . Chin J Interv Imaging Ther , 2021 , 18 ( 7 ): 406 - 410 .
Gemici AA , Gulsever AB , Tunca AF , et al . Shear wave elastography of the uterine cervix under different conditions with inter-operator agreement analysis [J ] . Pol J Radiol , 2020 , 85 : e245 - e249 .
Manchanda S , Vora Z , Sharma R , et al . Quantitative sonoelastographic assessment of the normal uterus using shear wave elastography:an initial experience [J ] . J Ultrasound Med , 2019 , 38 ( 12 ): 3183 - 3189 .
Du L , Lin MF , Wu LH , et al . Quantitative elastography of cervical stiffness during the three trimesters of pregnancy with a semiautomatic measurement program:a longitudinal prospective pilot study [J ] . J Obstet Gynaecol Res , 2020 , 46 ( 2 ): 237 - 248 .
Zhang M . Comparative study of real-time elastography and transvaginal ultrasonography in diagnosis of cervical occupied lesions [J ] . J Bengbu Med Coll , 2011 , 36 ( 4 ): 398 - 400,404 .
Zheng X , Yang C , Shi N . Study on the predictive value of cervical tissue shear-wave elastic imagingfor abortion and premature delivery [J ] . Chin J Ultrasound Med , 2022 , 38 ( 1 ): 99 - 102 .