1.重庆医科大学附属第二医院泌尿肾病中心,重庆 400010
2.陆军军医大学第一附属医院检验科,重庆 400038
Received:09 June 2022,
Published:28 August 2022
移动端阅览
申林果,王杨,刘玲,等.单抗原免疫微珠法在人组织相容性抗原反应抗体检测中的局限性及影响因素分析[J].重庆医科大学学报,2022,47(8):953-956.
Shen Linguo,Wang Yang,Liu Ling,et al.Analysis of the limitations and influencing factors of single antigen beads in the detection of human leukocyte antigen-antibody[J].Journal of Chongqing Medical University,2022,47(8):953-956.
申林果,王杨,刘玲,等.单抗原免疫微珠法在人组织相容性抗原反应抗体检测中的局限性及影响因素分析[J].重庆医科大学学报,2022,47(8):953-956. DOI: 10.13406/j.cnki.cyxb.003090.
Shen Linguo,Wang Yang,Liu Ling,et al.Analysis of the limitations and influencing factors of single antigen beads in the detection of human leukocyte antigen-antibody[J].Journal of Chongqing Medical University,2022,47(8):953-956. DOI: 10.13406/j.cnki.cyxb.003090.
人组织相容性抗原反应抗体(human leukocyte antigen-antibody,HLA-Ab)的检测已成为诊断及检测肾移植术后排斥反应的重要指标。单抗原免疫微珠法(single antigen beads,SAB)是一种灵敏度高、特异性强的HLA-Ab检测方法。然而,SAB检测结果的分析和解释较为复杂,需要综合考虑多方面的影响因素。本文将讨论使用此方法对HLA-Ab进行检测时的局限性、影响因素及解决办法。希望可以通过对上述问题的探讨来进一步完善SAB检测结果的解读与应用。
The detection of human leukocyte antigen-antibody(HLA-Ab)has become an important indicator for the diagnosis and detection of rejection after renal transplantation. Single antigen beads(SAB)is a highly sensitive and specific HLA-Ab detection method. However,the analysis and interpretation of SAB results are complex,and multiple factors need to be comprehensively considered. In this article,we will discuss the limitations,influencing factors and solutions for HLA-Ab detection using this method. It is hoped that the interpretation and application of SAB results can be further improved by discussing the above problems.
Lichvar AB , Tremblay S , Leino AD , et al . Reducing donor-specific antibody during acute rejection diminishes long-term renal allograft loss:comparison of early and late rejection [J ] . Transplantation , 2020 , 104 ( 11 ): 2403 - 2414 .
Chen XT , Qiu J , Wu ZX , et al . Using both plasma and urine donor-derived cell-free DNA to identify various renal allograft injuries [J ] . Clin Chem , 2022 , 68 ( 6 ): 814 - 825 .
El-Awar N , Lee J , Terasaki PI . HLA antibody identification with single antigen beads compared to conventional methods [J ] . Hum Immunol , 2005 , 66 ( 9 ): 989 - 997 .
Hansen EO , Dias NS , Burgos ICB , et al . Millipore xMap ® luminex(HATMAG-68K):an accurate and cost-effective method for evaluating Alzheimer's biomarkers in cerebrospinal fluid [J ] . Front Psychiatry , 2021 , 12 : 716686 .
Kong WW , Li Y , Cheng SH , et al . Luminex xMAP combined with Western blot improves HIV diagnostic sensitivity [J ] . J Virol Methods , 2016 , 227 : 1 - 5 .
Schlaf G , Bau D , Horstmann N , et al . Solid phase-based cross-matching for solid organ transplantation:currently out-of-stock but urgently required for improved allograft outcome [J ] . Histol Histopathol , 2020 , 35 ( 9 ): 937 - 948 .
郑 瑾 , 薛武军 . 肾移植排斥反应免疫风险评估与监测 [J ] . 器官移植 , 2021 , 12 ( 6 ): 643 - 650 .
Zheng J , Xue WJ . Assessment and monitoring of immune risk of kidney transplantation rejection [J ] . Organ Transplant , 2021 , 12 ( 6 ): 643 - 650 .
Koktathong K , Vejbaesya S , Bejrachandra S , et al . Flow cytometric crossmatch for kidney transplantation [J ] . J Med Assoc Thai , 2005 , 88 ( 6 ): 769 - 774 .
Martinez-Mier G , Vazquez-Crespo LV , Angeles-Hernández F , et al . Effect of panel-reactive antibody on graft survival in living kidney donor transplantation:analysis of 10 years in a transplant center in Veracruz,Mexico [J ] . Transplant Proc , 2020 , 52 ( 4 ): 1140 - 1142 .
Pei R , Lee JH , Shih NJ , et al . Single human leukocyte antigen flow cytometry beads for accurate identification of human leukocyte antigen antibody specificities [J ] . Transplantation , 2003 , 75 ( 1 ): 43 - 49 .
Güleç D , Soyöz M , Pirim I , et al . Comparison of single antigen bead-based,cell-based,and solid phase-based crossmatch methods [J ] . Transplant Proc , 2019 , 51 ( 4 ): 1016 - 1020 .
Burballa C , Pérez-Saéz MJ , Redondo-Pachón D , et al . Luminex screening first vs . direct single antigen bead assays:different strategies for HLA antibody monitoring after kidney transplantation [J ] . Hum Immunol , 2020 , 81 ( 6 ): 293 - 299 .
Visentin J , Guidicelli G , Couzi L , et al . Deciphering IgM interference in IgG anti-HLA antibody detection with flow beads assays [J ] . Hum Immunol , 2016 , 77 ( 11 ): 1048 - 1054 .
Sullivan HC , Liwski RS , Bray RA , et al . The road to HLA antibody evaluation:do not rely on MFI [J ] . Am J Transplant , 2017 , 17 ( 6 ): 1455 - 1461 .
Eberhard HP , Schmidt AH , Mytilineos J , et al . Common and well-documented HLA alleles of German stem cell donors by haplotype frequency estimation [J ] . HLA , 2018 , 92 ( 4 ): 206 - 214 .
Otten HG , Verhaar MC , Borst HPE , et al . The significance of pretransplant donor-specific antibodies reactive with intact or denatured human leucocyte antigen in kidney transplantation [J ] . Clin Exp Immunol , 2013 , 173 ( 3 ): 536 - 543 .
Gutiérrez-Larrañaga M , Riesco L , Guiral S , et al . Detection of antibodies to denatured human leucocyte antigen molecules by single antigen Luminex [J ] . HLA , 2021 , 97 ( 1 ): 52 - 59 .
Zerrouki A , Ouadghiri S , Benseffaj N , et al . High background in Luminex ® assay for HLA antibody screening:interest of Adsorb Out™ [J ] . Transpl Immunol , 2016 , 36 : 20 - 24 .
Guidicelli G , Visentin J , Franchini N , et al . Prevalence,distribution and amplitude of the complement interference phenomenon in single antigen flow beads assays [J ] . HLA , 2018 , 91 ( 6 ): 507 - 513 .
Popow I , Leitner J , Grabmeier-Pfistershammer K , et al . A comprehensive and quantitative analysis of the major specificities in rabbit anti-thymocyte globulin preparations [J ] . Am J Transplant , 2013 , 13 ( 12 ): 3103 - 3113 .
Barahona Afonso AF , João CMP . The production processes and biological effects of intravenous immunoglobulin [J ] . Biomolecules , 2016 , 6 ( 1 ): 15 .
Gu Y , Koh RWK , Lai ML , et al . Defining the structural basis for human leukocyte antigen reactivity in clinical transplantation [J ] . Sci Rep , 2020 , 10 ( 1 ): 18397 .
Garcia-Sanchez C , Usenko CY , Herrera ND , et al . The shared epitope phenomenon:a potential impediment to virtual crossmatch accuracy [J ] . Clin Transplant , 2020 , 34 ( 8 ): e13906 .
Choi J , Chandraker A . Immunologic risk assessment and approach to immunosuppression regimen in kidney transplantation [J ] . Clin Lab Med , 2019 , 39 ( 4 ): 643 - 656 .
Tafulo S , Malheiro J , Santos S , et al . Degree of HLA class II eplet mismatch load improves prediction of antibody-mediated rejection in living donor kidney transplantation [J ] . Hum Immunol , 2019 , 80 ( 12 ): 966 - 975 .
Lan JH , Tinckam K . Clinical utility of complement dependent assays in kidney transplantation [J ] . Transplantation , 2018 , 102 (1 Suppl 1 ): S14 - S22 .
Bailly E , Anglicheau D , Blancho G , et al . Prognostic value of the persistence of C1q-binding anti-HLA antibodies in acute antibody-mediated rejection in kidney transplantation [J ] . Transplantation , 2018 , 102 ( 4 ): 688 - 698 .
Bertrand D , Kaveri R , Laurent C , et al . Intensity of de novo DSA detected by immucor lifecodes assay and C3d fixing antibodies are not predictive of subclinical ABMR after kidney transplantation [J ] . PLoS One , 2021 , 16 ( 4 ): e0249934 .
Hayde N , Solomon S , Caglar E , et al . C1q-binding DSA and allograft outcomes in pediatric kidney transplant recipients [J ] . Pediatr Transplant , 2021 , 25 ( 2 ): e13885 .
Pernin V , Bec N , Beyze A , et al . IgG3 donor-specific antibodies with a proinflammatory glycosylation profile may be associated with the risk of antibody-mediated rejection after kidney transplantation [J ] . Am J Transplant , 2022 , 22 ( 3 ): 865 - 875 .
0
Views
3
下载量
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621