YAN Ji-lai,YANG Chun.Application and imaging characteristics of multi-slice CT angiography in the diagnosis of cerebral aneurysm[J].JOURNAL OF REGIONAL ANATOMY AND OPERATIVE SURGERY,2025,34(03):250-253.
YAN Ji-lai,YANG Chun.Application and imaging characteristics of multi-slice CT angiography in the diagnosis of cerebral aneurysm[J].JOURNAL OF REGIONAL ANATOMY AND OPERATIVE SURGERY,2025,34(03):250-253. DOI: 10.11659/jjssx.10E024036.
Application and imaging characteristics of multi-slice CT angiography in the diagnosis of cerebral aneurysm
To explore the application of multi-slice CT angiography (MSCTA) in the diagnosis of cerebral aneurysm (CA), and to analyze its imaging characteristics.
Methods
2
A total of 180 patients with suspected CA in the First Affiliated Hospital of Nanjing Medical University were enrolled, and all these patients underwent digital subtraction angiography (DSA) and MSCTA.Taking DSA results as the golden standard, the consistency of MSCTA in the diagnosis of CA was evaluated. The diagnostic coincidence rate of CA distribution, the maximum diameter of tumors and maximum width of tumor neck by the two methods were compared.
Results
2
In the 180 patients with suspected CA, DSA showed that there were 174 confirmed cases, including 240 aneurysms, while MSCTA showed that there were 168 confirmed cases, including 207 aneurysms.Taking DSA results as the golden standard, the s
ensitivity, specificity, accuracy and
Kappa
value of MSCTA in the diagnosis of CA were 96.55%, 100%, 96.67% and 0.651 respectively, showing good diagnostic consistency.The diagnostic coincidence rates of CA distributed in the internal carotid artery, vertebrobasilar artery, middle cerebral artery, clinoid process of internal carotid artery, cavernous sinus segment of internal carotid artery, anterior communicating artery and posterior communicating artery diagnosed by MSCTA were 81.82%, 83.33%, 85.71%, 87.50%, 86.67%, 90.00% and 90.00%, and the overall diagnostic coincidence rate was 86.25%.There was no significant difference in the maximum diameter of tumors or maximum width of tumor neck between MSCTA and DSA (
P
>
0.05).
Conclusion
2
The diagnostic value of MSCTA for CA is good, whihc has high diagnostic consistency with DSA and can be widely used in clinic.
关键词
Keywords
references
Umana GE , Spitaleri A , Fricia M , et al . Diffuse cerebral angiomatosis associated to basilar apex aneurysm [J]. Br J Neurosurg , 2023 , 37 ( 5 ): 1215 - 1219 . doi: 10.1080/02688697.2020.1836324 http://dx.doi.org/10.1080/02688697.2020.1836324 .
Liu Y , Guo G , Lin Z , et al . Occlusion of the anterior cerebral artery mimicking a cerebral aneurysm:clinical presentation and literature review [J]. J Neurol Surg A Cent Eur Neurosurg , 2022 , 83 ( 6 ): 606 - 610 . doi: 10.1055/s-0040-1722272 http://dx.doi.org/10.1055/s-0040-1722272 .
Zeynal M , Yalcin A . Before emergency aneurysm surgery,CTA or DSA? A single center experience [J]. Eur Rev Med Pharmacol Sci , 2023 , 27 ( 4 ): 1522 - 1527 . doi: 10.26355/eurrev_202302_31393 http://dx.doi.org/10.26355/eurrev_202302_31393 .
Yang G , Yan C , Zhang M , et al . Application effect of multi-slice spiral CT angiography combined with MRI in the diagnosis of cerebral aneurysm [J]. Biotechnol Genet Eng Rev , 2024 , 40 ( 3 ): 2982 - 2995 . doi: 10.1080/02648725.2023.2202995 http://dx.doi.org/10.1080/02648725.2023.2202995 .
Outcome of endovascular aortic repair under digital subtraction angiography in the treatment of Stanford type B aortic dissection
Diagnostic value of ultrasound blood quantitative parameters combined with BRAF in Hashimoto's thyroiditis complicated with thyroid carcinoma
Expression of serum miR-384 and LIN28B in diabetic retinopathy and their diagnostic value
Clinical value of color Doppler ultrasound and computed tomography angiography in diagnosis and interventional therapy of BuddChiari syndrome
Related Author
WU Chang-xue
LYU Jing
TIAN Ming-wu
WEN Zhi
WANG Zheng
WU Jian-qiang
TANG Li-jun
XU Ying
Related Institution
Department of Cardiothoracic and Vascular Surgery ,Deyang People's Hospital
Department of Ultrasound, Sir Run Run Hospital,Nanjing Medical University
Department of Nuclear Medicine,First Affiliated Hospital with Nanjing Medical University
Nanjing Dian Medical Laboratory Co., Ltd.
Department of Ophthalmology, Mianyang Hospital Affiliated to School of Medicine University of Electronic Science and Technology/ Mianyang Central Hospital