LIU Lie-hua,ZHOU Qiang.The placement techniques of pedicle screws through lumbar transpedicular dynamic stabilization[J].JOURNAL OF REGIONAL ANATOMY AND OPERATIVE SURGERY,2025,34(07):630-633.
LIU Lie-hua,ZHOU Qiang.The placement techniques of pedicle screws through lumbar transpedicular dynamic stabilization[J].JOURNAL OF REGIONAL ANATOMY AND OPERATIVE SURGERY,2025,34(07):630-633. DOI: 10.11659/jjssx.06E024101.
The placement techniques of pedicle screws through lumbar transpedicular dynamic stabilization
Lumbar transpedicular dynamic stabilization requires the internal fixation device to continuously provide mechanical support, and the correct placement of screws is the key to ensuring the surgical outcome. The placement of pedicle screws through lumbar transpedicular dynamic stabilization has higher requirements compared with the placement of conventional lumbar pedicle screw, which needs to precisely control the entry point, entry depth, and abduction angle of the pedicle screws, and avoid the potential risks such as the screws penetrating the lateral cortex of the pedicle simultaneously. Based on the clinical experience of our team, this article systematically summarizes the placement methods and operational points of pedicle screws through lumbar transpedicular dynamic stabilization, with the aim of providing a reference for clinical practice.
关键词
Keywords
references
Bogaert L , Thys T , Depreitere B , et al . Rehabilitation to improve outcomes of lumbar fusion surgery:a systematic review with meta-analysis [J]. Eur Spine J , 2022 , 31 ( 6 ): 1525 - 1545 . doi: 10.1007/s00586-022-07158-2 http://dx.doi.org/10.1007/s00586-022-07158-2 .
Onggo JR , Nambiar M , Maingard JT , et al . The use of minimally invasive interspinous process devices for the treatment of lumbar canal stenosis:a narrative literature review [J]. J Spine Surg , 2021 , 7 ( 3 ): 394 - 412 . doi: 10.21037/jss-21-57 http://dx.doi.org/10.21037/jss-21-57 .
Shen J , Wang Q , Wang Y , et al . Comparison between fusion and non-fusion surgery for lumbar spinal stenosis:a meta-analysis [J]. Adv Ther , 2021 , 38 ( 3 ): 1404 - 1414 . doi: 10.1007/s12325-020-01604-7 http://dx.doi.org/10.1007/s12325-020-01604-7 .
Costa F , Innocenzi G , Guida F , et al . Degenerative lumbar spine stenosis consensus conference:the Italian job.Recommendations of the spinal section of the Italian society of neurosurgery [J]. J Neurosurg Sci , 2021 , 65 ( 2 ): 91 - 100 . doi: 10.23736/S0390-5616.20.05042-0 http://dx.doi.org/10.23736/S0390-5616.20.05042-0 .
Schmoelz W , Huber JF , Nydegger T , et al . Influence of a dynamic stabilisation system on load bearing of a bridged disc:an in vitro study of intradiscal pressure [J]. Eur Spine J , 2006 , 15 ( 8 ): 1276 - 1285 . doi: 10.1007/s00586-005-0032-5 http://dx.doi.org/10.1007/s00586-005-0032-5 .
Gao W , Wang X , Chen Y , et al . Long-term efficacy of Waveflex semi-rigid-dynamic-internal-fixation system in delaying intervertebral disc degeneration at adjacent segments and improving spinal sagittal imbalance [J]. Sci Rep , 2024 , 14 ( 1 ): 10437 . doi: 10.1038/s41598-024-60940-8 http://dx.doi.org/10.1038/s41598-024-60940-8 .
Gan Y , Tu B , Li P , et al . Low magnitude of compression enhances biosynthesis of mesenchymal stem cells towards nucleus pulposus cells via the TRPV4-dependent pathway [J]. Stem Cells Int , 2018 , 2018 : 7061898 . doi: 10.1155/2018/7061898 http://dx.doi.org/10.1155/2018/7061898 .
Li YC , Feng XF , Pang XD , et al . Lumbar disc rehydration in the bridged segment using the BioFlex dynamic stabilization system:a case report and literature review [J]. World J Clin Cases , 2020 , 8 ( 10 ): 1958 - 1965 . doi: 10.12998/wjcc.v8.i10.1958 http://dx.doi.org/10.12998/wjcc.v8.i10.1958 .
Roy-Camille R , Saillant G , Mazel C . Internal fixation of the lumbar spine with pedicle screw plating [J]. Clin Orthop Relat Res , 1986 ( 203 ): 7 - 17 .
Magerl FP . Stabilization of the lower thoracic and lumbar spine with external skeletal fixation [J]. Clin Orthop Relat Res , 1984 ( 189 ): 125 - 141 .
Weinstein JN , Spratt KF , Spengler D , et al . Spinal pedicle fixation:reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement [J]. Spine (Phila Pa 1976) , 1988 , 13 ( 9 ): 1012 - 1018 . doi: 10.1097/00007632-198809000-00008 http://dx.doi.org/10.1097/00007632-198809000-00008 .
Yu HL , Lei W , Ma ZS , et al . Computer analysis of the safety of using three different pedicular screw insertion points in the lumbar spine in the Chinese population [J]. Eur Spine J , 2007 , 16 ( 5 ): 619 - 623 . doi: 10.1007/s00586-006-0243-4 http://dx.doi.org/10.1007/s00586-006-0243-4 .
Xing R , Dou Q , Li X , et al . Posterior dynamic stabilization with direct pars repair via Wiltse approach for the treatment of lumbar spondylolysis:the application of a novel surgery [J]. Spine (Phila Pa 1976) , 2016 , 41 ( 8 ): E494 - E502 . doi: 10.1097/BRS.0000000000 001295 http://dx.doi.org/10.1097/BRS.0000000000001295 .
Özer AF , Başak AT , Özbek MA , et al . Lumbar dynamic stabilization with 2-stage surgery:early results [J]. Int J Spine Surg , 2022 , 16 ( 4 ): 638 - 645 . doi: 10.14444/8306 http://dx.doi.org/10.14444/8306 .
Datir SP , Mitra SR . Morphometric study of the thoracic vertebral pedicle in an Indian population [J]. Spine (Phila Pa 1976) , 2004 , 29 ( 11 ): 1174 - 1181 . doi: 10.1097/00007632-200406010-00004 http://dx.doi.org/10.1097/00007632-200406010-00004 .
Chen Y , Zeng J , Guan J , et al . Reformatted computed tomographic evaluation of the thoracic pedicle in a Chinese population for the surgical application of transpedicular screw placement [J]. Surg Radiol Anat , 2010 , 32 ( 5 ): 463 - 468 . doi: 10.1007/s00276-009-0592-x http://dx.doi.org/10.1007/s00276-009-0592-x .
Amato V , Giannachi L , Irace C , et al . Accuracy of pedicle screw placement in the lumbosacral spine using conventional technique:computed tomography postoperative assessment in 102 consecutive patients [J]. J Neurosurg Spine , 2010 , 12 ( 3 ): 306 - 313 . doi: 10.3171/2009.9.SPINE09261 http://dx.doi.org/10.3171/2009.9.SPINE09261 .
Lotfinia I , Sayahmelli S , Gavami M . Postoperative computed tomography assessment of pedicle screw placement accuracy [J]. Turk Neurosurg , 2010 , 20 ( 4 ): 500 - 507 . doi: 10.5137/1019-5149.JTN.3215-10.1 http://dx.doi.org/10.5137/1019-5149.JTN.3215-10.1 .
Zhong Y , Luo L , Zhao C , et al . A study on the anatomical relationship of the lumbar extrapedicular puncture approach with the spinal nerve and its branches [J]. Spine (Phila Pa 1976) , 2021 , 46 ( 11 ): E611 - E617 . doi: 10.1097/BRS.0000000000003947 http://dx.doi.org/10.1097/BRS.0000000000003947 .
Localization of the sternocleidomastoid muscle in cervical vestibular evoked myogenic potential experiments in mice
Anatomical basis and clinical effect of radical styloid process bone (membrance) flap pedicled with the recurrent branch of radial artery to styloid process in the treatment of carpal scaphoid fracture
Efficacy and safety analysis of early surgical treatment for spinal thoracolumbar fracture without nerve injury
Neuroanatomical analysis of L5/S1 segments anterior lumbar interbody fusion
Anatomic study of pedicled buccal fat pad for temporomandibular joint ankylosis
Related Author
LIU Wen
LI Xuan-yi
XING Yong-chao
XING Zhong-cheng
ZHOU Yin-yin
TAO Sheng-xiang
FANG Zhi-hui
LEI Peng-cheng
Related Institution
Department of Otorhinolaryngology Head and Neck Surgery, Affiliated Hospital of Xuzhou Medical University
Department of Anatomy, Huaibei Vocational and Technical College
Jiangsu Provincial Laboratory for Artificial Auditory Engineering
Department of Otorhinolaryngology Head and Neck Surgery, Huaibei People's Hospital
Information Statistical Center, Sinopharm Dongfeng General Hospital Affiliated to Hubei University of Medicine