Dosage and safety evaluation of energy controllable steep pulse in treatment of implanted rabbit tumors
|更新时间:2025-01-15
|
Dosage and safety evaluation of energy controllable steep pulse in treatment of implanted rabbit tumors
Journal of Army Medical UniversityVol. 29, Issue 3, Pages: 213-215(2007)
作者机构:
1. 重庆医科大学附属第二医院妇产科
2. 重庆大学电气工程学院高电压与电工新技术实验室
3. 四川大学华西第二医院妇产科
作者简介:
基金信息:
DOI:
CLC:R451;R730.5;R454.1
Published:2007,
Published Online:15 February 2007,
稿件说明:
移动端阅览
DONG XIAO-JING, HU LI-NA, SUN CAI-XIN, et al. Dosage and safety evaluation of energy controllable steep pulse in treatment of implanted rabbit tumors. [J]. Journal of army medical university, 2007, 29(3): 213-215.
DOI:
DONG XIAO-JING, HU LI-NA, SUN CAI-XIN, et al. Dosage and safety evaluation of energy controllable steep pulse in treatment of implanted rabbit tumors. [J]. Journal of army medical university, 2007, 29(3): 213-215.DOI:
Dosage and safety evaluation of energy controllable steep pulse in treatment of implanted rabbit tumors
Objectives To explore the optimal dosage and evaluate the safety of energy controllable steep pulse (ECSP) in the treatment of implanted rabbit tumor. Methods The models of VX
2
breast carcinoma were established in 10 New England rabbits
and then the animals were given ECSP treatment under orthogonality designed dosages of ECSP. The volumes of necrosis tumors were measured by TTC staining. The best dosage was analyzed by intuitionistic analysis. The models of VX
2
liver carcinoma were established in 20 New England rabbits. The normal tissues surrounding the tumor were extracted
the DNA fragmentation
analysis and comet assay were carried out. Results Voltage took the priority among the 4 parameters
and for best dosage they were 150 V for voltage
100 Hz for frequency
0.01μm for pulse width
and 15 min for time if the interaction of these 4 factors was not considered. The electrophoresis of DNA in the peripheral normal tissue was an integrity straining after ECSP treatment. No comet tailing was observed
indicating no DNA lesions after ECSP treatment. Conclusion The best dosage is 150 V for voltage
100 Hz for frequency
0.01 μm for pulse width and treating for 15 min. The ECSP is verified to be safe.
关键词
能量可控陡脉冲VX2肿瘤治疗剂量安全性
Keywords
energy controllable steep pulseVX2 tumordosagesafety
Tacrolimus versus mycophenolate mofetil for therapy of Henoch-Schonlein purpura nephritis: a retrospective comparison trial
Efficacy and safety of 2 asparaginase preparations in induction treatment of adult acute lymphoblastic leukemia
Bone cementinjectable cannulated pedicle screw augmented with polymethylmethacrylate in osteoporotic spine: a mid and longterm clinical efficacy of 128 cases
Safety of canagliflozin, empagliflozin and dapagliflozin for T2DM patients: a network meta-analysis
Related Author
ZHAO Jinghong
XIONG Jiachuan
QIN Jian
Li Lina
Zhao Hongwen
Shen Bingbing
Mei Mei
Wu Xiongfei
Related Institution
Department of Nephrology, Chongqing Key Laboratory for Prevention and Treatment of Chronic Kidney Disease, Chongqing Clinical Research Center of Kidney and Urinary Diseases, Second Affiliated Hospital, Army Medical University (Third Military Medical University)
Department of Nephrology, Southwest Hospital, Third Military Medical University
Department of Hematology, Nanfang Hospital, Southern Medical University
Department of Orthopaedics, Center of Orthopaedic Surgery, First Affiliated Hospital of Army Medical University (Third Military Medical University)
Department of Pharmacy, Chongqing Three Gorges Central Hospital, Wanzhou