Electron beam computed tomography vs transthoracic echocardiography in diagnosis of congenital heart disease
|更新时间:2025-01-15
|
Electron beam computed tomography vs transthoracic echocardiography in diagnosis of congenital heart disease
Journal of Army Medical UniversityVol. 29, Issue 6, Pages: 555-557(2007)
作者机构:
第三军医大学新桥医院放射科
作者简介:
基金信息:
DOI:
CLC:R540.45;R541.1;R814.42
Published:2007,
Published Online:30 March 2007,
稿件说明:
移动端阅览
LI KE, ZOU LI-GUANG, SUN QING-RONG, et al. Electron beam computed tomography vs transthoracic echocardiography in diagnosis of congenital heart disease. [J]. Journal of army medical university, 2007, 29(6): 555-557.
DOI:
LI KE, ZOU LI-GUANG, SUN QING-RONG, et al. Electron beam computed tomography vs transthoracic echocardiography in diagnosis of congenital heart disease. [J]. Journal of army medical university, 2007, 29(6): 555-557.DOI:
Electron beam computed tomography vs transthoracic echocardiography in diagnosis of congenital heart disease
Objective To explore the value of electron beam computed tomography (EBCT) and transthoracic echocardiography (TTE) in the diagnosis of congenital heart disease (CHD). Methods Thirty-two patients diagnosed as CHD by TTE underwent EBCT for cardiovascular examination. The results were compared with the results by cardiovascular angiography and from surgery. Results The total diagnosis accordance rate by EBCT was 87.5% (28/32) and that by TTE was 78.1% (25/32). The diagnosis accuracy rate in extracardiac deformities and ventricular-arterial connections was 96.6% (57/59)
higher than 66.1% (39/59) by TTE. However
the diagnosis accuracy rate in intracardiac deformities by TTE was 97.7% (43/44)
higher than 81.8% (36/44) by EBCT. The combination of EBCT and TTE can raise the diagnosis accuracy rate to 96.9% (31/32). Conclusion EBCT is of significant value in CHD diagnosis
especially in the diagnosis of extracardiac deformities and ventricular-arterial connections deformities. The combination of EBCT and TTE can raise the diagnosis accuracy rate of various kinds of CHD.
Evaluation of rabbit left ventricular systolic function at low temperature by two-dimensional speckle-tracking echocardiography
Change of cardiac function in healthy young males following rapid travel to highlands
Clinical value of left ventricle opacification in evaluating regional wall motion abnormalities in patients with coronary artery disease
Value of speckle tracking imaging in postoperative follow-up of alcohol septal ablation for hypertrophic obstructive cardiomyopathy: report of 19 cases
Related Author
DONG Yingna
LIU Fang1
WANG Yi1
WU Lulu1
CAO Junying2
WANG Dongni1
Li Suzhi
Pan Li
Related Institution
Postgraduate Training Base, Department of Ultrasonography, General Hospital of Northern Theater Command, Jinzhou Medical University
Department of High Altitude Medicine, Key Laboratory of High Altitude Medicine of Ministry of Education, Key Laboratory of High Altitude Physiology and Mountain Sickness Research of PLA, College of High Altitude Military Medicine, Third Military Medical University
General Hospital of Tibet Military Command, Lhasa, Tibet Autonomous Region,
Department of Ultrasonography, Department of Cardiology, Chongqing Institute of Interventional Cardiology, Southwest Hospital, Third Military Medical University