Simulation of jugular foramen region exposure through suboccipito-retrosigmoidal approach by virtual reality system
|更新时间:2025-01-15
|
Simulation of jugular foramen region exposure through suboccipito-retrosigmoidal approach by virtual reality system
Journal of Army Medical UniversityVol. 35, Issue 21, Pages: 2359-2362(2013)
作者机构:
解放军第309医院神经外科
作者简介:
基金信息:
DOI:
CLC:R319;R322;R323.1
Published:2013,
Published Online:15 November 2013,
稿件说明:
移动端阅览
TANG KE, ZHOU JING’AN, ZHOU QING, et al. Simulation of jugular foramen region exposure through suboccipito-retrosigmoidal approach by virtual reality system. [J]. Journal of army medical university, 2013, 35(21): 2359-2362.
DOI:
TANG KE, ZHOU JING’AN, ZHOU QING, et al. Simulation of jugular foramen region exposure through suboccipito-retrosigmoidal approach by virtual reality system. [J]. Journal of army medical university, 2013, 35(21): 2359-2362.DOI:
Simulation of jugular foramen region exposure through suboccipito-retrosigmoidal approach by virtual reality system
Objective To demonstrate the regional anatomy features of jugular foramen region in suboccipito-retrosigmoidal approach simulated by virtual reality technique. Methods CT and MRI scanning were performed to 5 adult cadaver heads
and then
silicone mixed with contrast agent was injected into the arterial and venous systems respectively. CT scanning were performed again after above 2 times of injection. Brainstem and cranial nerves were exposed after resecting partial cerebellar hemisphere by suboccipito-retrosigmoidal approach in the bilateral dissection of cadaver head. MRI scaning were performed again. Image data was inputted into Vitrea virtual reality system to establish three-dimensional anatomy model of jugular foramen region and simulate suboccipito-retrosigmoidal approach. Superior margin of inner acoustic canal entrance
anterior and posterior margin of jugular foramen were selected as osseous mark points to measure the distance in cadaver heads and computed models respectively. Bland-Altman method was used for the uniformity of checking. Results Spacial relationships of nerves
vessels and osseous structures were displayed well in virtual reality three-dimensional model of jugular foramen region. Comparative analysis between cadaver heads and computed models by Bland-Altman method showed that bias for distance between superior margin of inner acoustic canal entrance and anterior margin of jugular foramen
superior margin of inner acoustic canal entrance and posterior margin of jugular foramen
anterior and posterior margin of jugular foramen were 0.060
0.062
and 0.017
respectively
and 95% confidence intervals were -0.255 to 0.375
-0.357 to 0.481
and -0.265 to 0.299
respectively. Good consistency was demonstrated in scatter diagram. Conclusion Data measured in three-dimensional anatomic model of jugular foramen region is proven to be accurate by cadaver dissection
which is helpful to launch research for protection of nerves and vessels.