Establishment of a uniaxial cyclic stretching model of tendon stem cells in vitro
|更新时间:2025-01-15
|
Establishment of a uniaxial cyclic stretching model of tendon stem cells in vitro
Journal of Army Medical UniversityVol. 36, Issue 11, Pages: 1142-1146(2014)
作者机构:
1. 第三军医大学西南医院骨科,全军矫形外科中心
2. 重庆市机电设计研究院
作者简介:
基金信息:
DOI:
CLC:R322.74;R-33;R329.2
Published:2014,
Published Online:15 June 2014,
稿件说明:
移动端阅览
YANG GUANGHUA, TANG KANGLAI, MA LIN, et al. Establishment of a uniaxial cyclic stretching model of tendon stem cells in vitro. [J]. Journal of army medical university, 2014, 36(11): 1142-1146.
DOI:
YANG GUANGHUA, TANG KANGLAI, MA LIN, et al. Establishment of a uniaxial cyclic stretching model of tendon stem cells in vitro. [J]. Journal of army medical university, 2014, 36(11): 1142-1146.DOI:
Establishment of a uniaxial cyclic stretching model of tendon stem cells in vitro
Objective To design a uniaxial cyclic stretching model of tendon stem cells (TSCs)
in vitro
. Methods After our silicone-made micro-grooved dishes were analyzed for strain distributions by the finite element software ABAQUS. Freshly isolated and identified TSCs were cultured on the dishes
and then observed for their adherent growth. A programmable logic controller (PLC) was used to make the mechanic
al running parts of the model do cyclically stretching for the dishes. Dishes were divided into 16 groups
with the cyclic stretching for 24 h under different stretch frequencies (0.5
1.0
2.0 and 3.0 Hz) and strains (4%
8%
16% and 20%). The actual running frequency and displacement distance of these silicone dishes were measured. Inverted microscopy was employed to observe the falling off or floating of the TSCs. F-actin in the cytoskeleton were observed by laser confocal scanning microscopy when the cells were stretched for 8 or 12 h under the frequency of 1 Hz and strain of 8%. Results The strain distribution was uniform on the self-made silicone dishes. Effective strain range of the bottom membrane accounted for about 91% of its total area in the dishes. When cultured on the dishes for 10 h
all TSCs attached on the dishes and grew along with microgroove direction. Stretching model ran stably under different stretching conditions. There was no significant difference in the actual running frequency and strain displacement distance of the silicone dishes with the set frequency and theoretical strain displacement distance (
P
>0.05). No obvious falling off or floating was observed in the TSCs cultured on the dishes. F-actin filaments seemed much thinner
and some of them were broken
and the red fluorescence dyeing (F-actin) was weakened and unevenly distributed in the streched cells than the cells without stretching. Conclusion Our established uniaxial cyclic stretching model is easy to operate
with wild range of parameters
and is used to simulate conditions for adherent cells under different biomechanical loading
Isolation and identification of tendon stem cells from rat Achilles’s tendon
Related Author
Ma Xiaojuan
Wang Chao
Pang Qin
Du Quangao
Fu Gang
Hu Chao
Tang Kanglai
Chen Wan
Related Institution
Department of Implant Dentistry, Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing Key Laboratory of Oral Biomedical Engineering of Higher Education, Stomatological Hospital of Chongqing Medical University
Department of Orthopedics, Southwest Hospital, Third Military Medical University