Clinical value of optic nerve sheath diameter by ultrasonic detection in the diagnosis and treatment of patients with acute increased intracranial pressure
返回论文页
|更新时间:2024-02-04
|
Clinical value of optic nerve sheath diameter by ultrasonic detection in the diagnosis and treatment of patients with acute increased intracranial pressure
Journal of Clinical Ultrasound in MedicineVol. 25, Issue 12, (2023)
作者机构:
广元市第一人民医院
作者简介:
基金信息:
DOI:
CLC:
Published:2023,
Published Online:2 January 2024,
扫 描 看 全 文
Clinical value of optic nerve sheath diameter by ultrasonic detection in the diagnosis and treatment of patients with acute increased intracranial pressure. [J]. Journal of Clinical Ultrasound in Medicine 25(12).(2023)
DOI:
Clinical value of optic nerve sheath diameter by ultrasonic detection in the diagnosis and treatment of patients with acute increased intracranial pressure. [J]. Journal of Clinical Ultrasound in Medicine 25(12).(2023)DOI:
Clinical value of optic nerve sheath diameter by ultrasonic detection in the diagnosis and treatment of patients with acute increased intracranial pressure
Objective To explore the clinical value of optic nerve sheath diameter (ONSD) by ultrasonic detection in the diagnosis and treatment of patients with acute increased intracranial pressure (ICP). Methods A total of 180 patients with acute increased ICP in the hospital were enrolled between March 2020 and March 2023. ONSD and ICP were collected before surgery (T0)
after anesthesia (T1)
at the beginning of surgery (T2)
immediately after surgery (T3) and immediately after awaking (T4). The relationship between ONSD and ICP at different time points was analyzed. According to scores of Glasgow Outcome Scale (GOS)
they were divided into good prognosis group (157 cases) and poor prognosis group (23 cases). ONSD in the two groups was compared before surgery and immediately after surgery. The correlation between ONSD and GOS score was analyzed. The predictive value of ONSD for prognosis in patients with perioperative acute increased ICH was analyzed by receiver operating characteristic (ROC) curves. Results From T0-T2
there was no significant change in ONSD or ICP
but which were significantly decreased from T3-T4 (P<0.05). The results of Pearson correlation analysis showed that ONSD was positively correlated with ICP from T0-T4 (P<0.05). After surgery
levels of ONSD and ICP were decreased in both groups
which were lower in good prognosis group than poor prognosis group (P<0.05). The results of Spearman correlation analysis showed that ONSD and ICP were negatively correlated with GOS score immediately after surgery (P<0.05). The results of ROC curves analysis showed that AUC values of ONSD and ICP for predicting poor prognosis immediately after surgery were 0.886 and 0.782
which were of good predictive value (P<0.05). Conclusion ONSD by ultrasonic detection can effectively evaluate ICP in patients with acute increased ICP
Predictive value of optic nerve sheath diameter of ultrasound quantification and plaque characteristics for adverse events in ischemic stroke
Application value of ultrasoundmeasuredoptic nerve sheath diameter combined with flash visual evoked potential in evaluating intracranial pressure of patients with craniocerebral injury
Diagnosis of supraspinatus myositis by ultrasonic power Doppler and elasticity and correlation analysis with visual acuity
Ultrasound diagnosis of hand and foot melanoma: a case report
Related Author
zhaoyujun
jiasong
岳红
王小文
贺雪梅
李林峻
张勇
陈丹
Related Institution
Qianjiang District Hospital of traditional Chinese medicine
保定市第二中心医院重症医学科
The First Affiliated Hospital of Chongqing Medical University