Clinical value of CEUS LI-RADS in the diagnosis of properties of focal liver lesions with diameter≤3 cm
返回论文页
|更新时间:2024-03-02
|
Clinical value of CEUS LI-RADS in the diagnosis of properties of focal liver lesions with diameter≤3 cm
Journal of Clinical Ultrasound in MedicineVol. 25, Issue 10, (2023)
作者机构:
江苏南通大学附属肿瘤医院
作者简介:
基金信息:
DOI:
CLC:
Published:2023,
Published Online:30 October 2023,
扫 描 看 全 文
Clinical value of CEUS LI-RADS in the diagnosis of properties of focal liver lesions with diameter≤3 cm. [J]. Journal of Clinical Ultrasound in Medicine 25(10).(2023)
DOI:
Clinical value of CEUS LI-RADS in the diagnosis of properties of focal liver lesions with diameter≤3 cm. [J]. Journal of Clinical Ultrasound in Medicine 25(10).(2023)DOI:
Clinical value of CEUS LI-RADS in the diagnosis of properties of focal liver lesions with diameter≤3 cm
Objective To explore the clinical value of contrast-enhanced ultrasound liver imaging reporting and data system (CEUS LI-RADS) in the diagnosis of properties of focal liver lesions (FLLs) with diameter≤3 cm. Methods 82 patients with FLLs from July 2019 to November 2022 were selected as the study subjects. All patients underwent conventional ultrasound and contrast-enhanced ultrasound. Taking pathological examination result as the reference standard
the diagnostic value of CEUS LI-RADS and conventional ultrasound on benign and malignant FLLs was analyzed
and the diagnostic accuracy rate of CEUS LI-RADS on FLLs with different diameters was compared. Results Pathological examination showed that there were 3 cases of benign lesions (2 cases f atypical liver solitary fibrous tumors
1 case of hepatic hemangioma) and 79 cases of malignant lesions [40 cases of hepatocellular carcinoma (HCC)
14 cases of cholangiocarcinoma
23 cases of metastatic carcinoma
1 case of pleomorphic rhabdomyosarcoma
1 case of epithelioid angiosarcoma). The accuracy rate of LI-RADS in diagnosing FLLs was 90.24% (74/82). The consistency of CEUS LI-RADS with pathological examination result (kappa=0.553) was higher than that of conventional ultrasound (Kappa=0.266). The AUC of CEUS LI-RADS in the diagnosis of benign and malignant liver lesions was greater than that of conventional ultrasound (P
<
0.05). The accuracy rates of CEUS LI-RADS in the diagnosis of FLLs with diameters of 2-3cm
1-2cm and
<
1cm were 94.74% (36/38)
91.18% (31/34) and 70.00% (7/10) respectively. The accuracy rate of CEUS LI-RADS in the diagnosis of FLLs with diameter of 2-3cm was higher than that in the diagnosis of FLLs with diameter
<
1cm (χ
2
=
5.191
P=0.023). Conclusion CEUS LI-RADS can be used to judge the malignant probability of FLLs
and LI-RADS LR-5 has diagnostic value on malignant FLLs.
关键词
超声造影肝脏影像报告和数据管理系统肝脏局灶性病变直径≤3cm病灶性质
Keywords
Contrast-enhanced ultrasound liver imaging reporting and data systemFocal liver lesionsDiameter ≤ 3cmLesion properties