Conventional ultrasound combined with shear wave elastography to distinguish pleomorphic adenoma from Warthin tumor of parotid: comparative with MRI
返回论文页
|更新时间:2024-03-02
|
Conventional ultrasound combined with shear wave elastography to distinguish pleomorphic adenoma from Warthin tumor of parotid: comparative with MRI
Journal of Clinical Ultrasound in MedicineVol. 25, Issue 10, (2023)
作者机构:
南京医科大学第一附属医院
作者简介:
基金信息:
DOI:
CLC:
Published:2023,
Published Online:30 October 2023,
扫 描 看 全 文
Conventional ultrasound combined with shear wave elastography to distinguish pleomorphic adenoma from Warthin tumor of parotid: comparative with MRI. [J]. Journal of Clinical Ultrasound in Medicine 25(10).(2023)
DOI:
Conventional ultrasound combined with shear wave elastography to distinguish pleomorphic adenoma from Warthin tumor of parotid: comparative with MRI. [J]. Journal of Clinical Ultrasound in Medicine 25(10).(2023)DOI:
Conventional ultrasound combined with shear wave elastography to distinguish pleomorphic adenoma from Warthin tumor of parotid: comparative with MRI
Objective To explore the value of conventional ultrasound (US) combined with shear wave elastography (SWE) in the differential diagnosis of parotid pleomorphic adenoma and Warthin''s tumor
and compare the diagnostic efficiency with MRI. Methods Select 81 cases of parotid gland tumors confirmed by pathology
58 cases of pleomorphic adenoma and 23 cases of Warthin''s tumor
Compare the US characteristics of two lesions: Shape
boundary
hyper echo
anechoic
blood flow distribution
blood flow grade and SWE quantitative parameters: Emax
Emean
Emin
SD. Results There were statistical significance in the tumor Shape
hyper echo
anechoic
blood flow distribution
blood flow grade and Emax
Emean
SD between the pleomorphic adenoma and Warthin''s tumor (P<0.05)
The area under the ROC (AUC) of the Logistic equation predicted values of US
SWE and US+SWE are 0.881
0.837
0.962. The diagnostic sensitivity
specificity
accuracy of US+SWE and MRI were (85%
87.27%)
(88%
84%)
(86.2%
86.2%)
The difference was not statistically significant (P>0.05)
the diagnostic value is consistent. Conclusions Conventional ultrasound combined with shear wave elastography can improve the ability of differential diagnosis pleomorphic adenoma and Warthin''s tumor of parotid
and the diagnostic efficiency is comparable to MRI.
Research progress of echocardiography in evaluation of myocardial fibrosis
The application value of shear wave elastography in evaluating the treatment effect of testicular epididymitis caused by testicular appendage torsion in children
Application of transperineal shear wave elastography combined with anterior chamber structure parameters in POP screening for puerperaeundergoing natural delivery
Clinical study of real-time shear-wave elastography ultrasound in evaluating the severity of peritoneal sclerosis in peritoneal dialysis patientsZhang Yutong, Chen Yujun, Li Xiaoju, Wang Xiaoli, Li Manying,Xie Xiaoyan, Xu Ming
Related Author
周玮珺
杨敏
刘勇
徐平
吴兰英
王颖
肖榕
冷晨蕾
Related Institution
安徽医科大学第一附属医院
南京鼓楼医院
Department of ultrasound,Beijing Shijitan Hospital,Capital Medical University