Effect of different administration routes of penehyclidine hydrochloride on respiratory mechanics of patients undergoing gynecological laparoscopic surgery
|更新时间:2025-09-11
|
Effect of different administration routes of penehyclidine hydrochloride on respiratory mechanics of patients undergoing gynecological laparoscopic surgery
Journal of Chongqing Medical UniversityVol. 47, Issue 6, Pages: 740-744(2022)
作者机构:
四川省医学科学院/四川省人民医院麻醉科,成都,610072
作者简介:
基金信息:
DOI:
CLC:R614.1
Published:2022
稿件说明:
移动端阅览
Min Weixiang. Effect of different administration routes of penehyclidine hydrochloride on respiratory mechanics of patients undergoing gynecological laparoscopic surgery[J]. Journal of chongqing medical university, 2022, 47(6): 740-744.
DOI:
Min Weixiang. Effect of different administration routes of penehyclidine hydrochloride on respiratory mechanics of patients undergoing gynecological laparoscopic surgery[J]. Journal of chongqing medical university, 2022, 47(6): 740-744.DOI:
Effect of different administration routes of penehyclidine hydrochloride on respiratory mechanics of patients undergoing gynecological laparoscopic surgery
目的: 探讨妇科腹腔镜手术时盐酸戊乙奎醚(penehyclidine hydrochloride,PCHE)在静脉滴注与雾化吸入不同给药途径时对患者呼吸力学的影响。方法: 选取四川省人民医院行妇科腹腔镜手术的患者150例,随机分为静脉滴注组、雾化吸入组、空白对照组,每组各50例。3组患者分别在麻醉诱导前15 min给予静脉滴注PCHE 1 mL、雾化吸入PCHE 1 mL和静脉滴注生理盐水1 mL。收集人工气腹前(T1)、气腹后30 min(T2)、气腹后60 min(T3)、拔管后10 min(T4)呼吸力学指标[气道峰压、气道阻力、气道平台压、呼气末二氧化碳分压(partial pressure of end-tidal carbon dioxide,PetCO2)]、循环力学指标[心率(heart rate,HR)、血压(blood pressure,BP)]及血气分析指标[氧分压(partial pressure of oxygen,PaO2)、二氧化碳分压(partial pressure of carbon dioxide,PaCO2)、氧合指数(partial pressure of oxygen in arterial blood/fractional concentration of inspiratory oxygen,oxygenation index,PaO2/FiO2)]。结果: 在T2和T3时刻,静脉滴注组和雾化吸入组的气道峰压、气道阻力、气道平台压值明显低于空白对照组(P<0.05),且雾化吸入组呼吸力学指标值均明显低于静脉滴注组(P<0.05)。在T2、T3和T4时刻,雾化吸入组和静脉滴注组PaO2、PaO2/FiO2值明显高于空白对照组(P<0.05),T2、T3时刻雾化吸入组PaO2、PaO2/FiO2值明显高于静脉滴注组(P<0.05);T2、T3和T4时刻雾化吸入组和静脉滴注组PaCO2值明显低于空白对照组(P<0.05),而雾化吸入组与静脉滴注组PaCO2值差异无统计学意义(P>0.05)。3组间HR、BP值差异无统计学意义(P>0.05)。体位改变前后,3组间呼吸力学指标值、循环力学指标值及血气分析指标值差异无统计学意义(P>0.05)。结论: 妇科腹腔镜手术时人工气腹可引起呼吸道力学和血气分析指标变化,应用PCHE可有效改善患者的气道压力和呼吸内环境,为临床给药和麻醉管理提供科学依据。
Abstract
Objective: To investigate the effects of different administration routes of intravenous drip and aerosol inhalation of penehyclidine hydrochloride (PCHE) on respiratory mechanics of patients undergoing gynecological laparoscopic surgery. Methods: A total of 150 patients undergoing gynecological laparoscopic surgery in Sichuan Provincial People's Hospital were randomized into intravenous drip group
aerosol inhalation group and blank control group
with 50 cases in each group. The three groups of patients were given intravenous drip with PCHE 1 mL
aerosolinhalation with PCHE 1 mL and intravenous drip with saline 1 mL 15 min before induction of anesthesia
respectively. Respiratory mechanics indexes (Peak
Raw
Plat
PetCO2)
circulatory mechanics indexes (HR
BP) and blood gas analysis indexes (PaO2
PaCO2
PaO2/FiO2) were collected before artificial pneumoperitoneum (T1)
30 min after pneumoperitoneum (T2)
60 min after pneumoperitoneum (T3) and 10 min after extubation (T4). Results: At T2 and T3
the Peak
Plat and Raw values of intravenous drip group and aerosol inhalation group were significantly lower than those of blank control group (P<0.05)
and the respiratory mechanics indexes of aerosol inhalation group were significantly lower than those of intravenous drip group (P<0.05). At T2
T3 and T4
the PaO2 and PaO2/FiO2 values of aerosol inhalation group and intra venous drip group were significantly higher than those of blank control group (P<0.05)
PaO2 and PaO2/FiO2 values of aerosol inhalation group at T2 and T3 were significantly higher than those of intravenous drip group (P<0.05). PaCO2 values of aerosol inhalation group and intravenous drip group at T2
T3 and T4 were significantly lower than those of blank control group (P<0.05). And there was no significant difference in PaCO2 values between intravenous drip group and aerosol inhalation group (P>0.05). There was no significant difference in HR and BP values among the three groups (P>0.05). There was no significant difference in respiratory mechanics index
circulatory mechanics index and blood gas analysis index among the three groups after the change of body position (P>0.05). Conclusion: Artificial pneumoperitoneum during gynecological laparoscopic surgery could cause changes in respiratory tract mechanics and blood gas analysis. PCHE can effectively improve the airway pressure and internal respiratory environment of patients
which provides a scientific basis for clinical administration and anesthesia management in gynecological laparoscopic surgery.
Curative effect of ear acupoint bean pressing in improving gastrointestinal function and gastrointestinal hormone level after laparoscopic hysteromyoma operation
Research advances and current status of robotic hepatectomy
Impact of laparoscopic nephron-sparing nephrectomy on renal function and prognosis in patients with renal cell carcinoma
Factors affecting the outcome of partial nephrectomy in patients with stage T1 renal cancer
Related Author
Zhang Wenye
You Xiaofeng
Xiao Jing
Zheng Liurong
Liu Jilai
Wang Mei
Xiang Shujing
Huang Jinhua
Related Institution
School of Nursing,Fujian University of Traditional Chinese Medicine
Department of Gynecology,The People’s Hospital Affiliated to Fujian University of Traditional Chinese Medicine
Department of Hepatobiliary Surgery,The Second Affiliated Hospital of Chongqing Medical University
Department of Urology,The First Affiliated Hospital of Chongqing Medical University
Department of Urinary Surgery,The First Affiliated Hospital of Chongqing Medical University