Influence of residual ferrule location on stress distribution of maxillary premolar restored with post-and-core crown:a three-dimensional finite element analysis
返回论文页
|更新时间:2023-12-22
|
Influence of residual ferrule location on stress distribution of maxillary premolar restored with post-and-core crown:a three-dimensional finite element analysis
Journal of Chongqing Medical UniversityVol. 43, Issue 10, Pages: 1344-1348(2018)
作者机构:
作者简介:
基金信息:
DOI:
CLC:
Published:2018,
扫 描 看 全 文
Influence of residual ferrule location on stress distribution of maxillary premolar restored with post-and-core crown:a three-dimensional finite element analysis. [J]. Journal of Chongqing Medical University 43(10):1344-1348(2018)
DOI:
Influence of residual ferrule location on stress distribution of maxillary premolar restored with post-and-core crown:a three-dimensional finite element analysis. [J]. Journal of Chongqing Medical University 43(10):1344-1348(2018)DOI:
Influence of residual ferrule location on stress distribution of maxillary premolar restored with post-and-core crown:a three-dimensional finite element analysis
Objective:To investigate the stress distribution of maxillary premolar with different residual ferrule locations after post-core crown restoration using the finite element analysis. Methods:An extracted maxillary premolar was embedded in acrylic resin block. Cone-beam CT scan and a finite element analysis software were used to establish five models of post-core crown restoration with dif-ferent residual ferrule locations(group A:teeth with a circular ferrule;group B:teeth with a complete palatal ferrule;group C:teeth with a complete buccal ferrule;group D:teeth with a complete mesial ferrule;group E:teeth with a complete distal ferrule;the height of the ferrule was 2 mm in all groups). A load of 200 N at a 45° angle to the long axis of the tooth was applied at the top 1/3 of the lingual surface of the buccal cusp. The maximum von Mises stress and the maximum principal stress were analyzed. Results:Group C had the highest maximum von Mises stress of 64.53 MPa,while group A had the lowest maximum von Mises stress of 50.87 MPa. The maximum von Mises stresses in group B,group D,and group E were 55.31,60.61 and 59.73 MPa,respectively. The maximum principal stresses in groups A to E were 43.04,43.60,47.34,45.39 and 46.91 MPa,respectively. Conclusion:A complete ferrule can effectively prevent stress concentration at the dentinal tissue of the tooth and enhance fracture resistance of the diseased tooth. When the re-maining dentinal tissue is not sufficient,preservation of the palatal ferrule can protect the integrity of the adhesive layer,increase the fracture resistance of the adhesive layer between the dentin and resin,and thus enhance the anti-fracture ability of the diseased tooth.
关键词
牙本质肩领位置上颌前磨牙桩核冠有限元分析
Keywords
ferrule locationmaxillary premolarpost-core crownfinite element analysis
Influence of residual ferrule location on stress distribution of maxillary premolar restored with post-and-core crown: a three-dimensional finite element analysis
Comparison of different treatment methods for Vancouver type B2 fracture based on finite element analysis
Related Author
Yu LI
Shanwen XU
Jiangliang SONG
Sanqing SU
Yuanzhao HUANG
Wei WANG
Xing WEI
Chentai WU
Related Institution
School of Civil Eng., Xi’an Univ. of Architecture and Technol.
School of Civil Eng., Southwest Jiaotong Univ.
Department of Orthopedics,China National Petroleum Corporation Central Hospital
Department of Invasive Technology,China National Petroleum Corporation Central Hospital
Department of Prosthondontics,the Affiliated Stomatology Hospital,Chongqing Medical University