Value of high-resolution three-dimensional contrast-enhanced magnetic resonance venography combined with three-dimensional T1-weighted magnetic resonance imaging in surgical planning for stereotactic electroencephalography
返回论文页
|更新时间:2023-12-22
|
Value of high-resolution three-dimensional contrast-enhanced magnetic resonance venography combined with three-dimensional T1-weighted magnetic resonance imaging in surgical planning for stereotactic electroencephalography
Journal of Chongqing Medical UniversityVol. 44, Issue 1, Pages: 85(2019)
作者机构:
苏州大学附属第一医院神经外科,苏州,215000
作者简介:
基金信息:
DOI:
CLC:
Published:2019,
扫 描 看 全 文
Gao Wei, Bi Yongfeng, Ye Ming, et al. Value of high-resolution three-dimensional contrast-enhanced magnetic resonance venography combined with three-dimensional T1-weighted magnetic resonance imaging in surgical planning for stereotactic electroencephalography. [J]. Journal of Chongqing Medical University 44(1):85(2019)
DOI:
Gao Wei, Bi Yongfeng, Ye Ming, et al. Value of high-resolution three-dimensional contrast-enhanced magnetic resonance venography combined with three-dimensional T1-weighted magnetic resonance imaging in surgical planning for stereotactic electroencephalography. [J]. Journal of Chongqing Medical University 44(1):85(2019)DOI:
Value of high-resolution three-dimensional contrast-enhanced magnetic resonance venography combined with three-dimensional T1-weighted magnetic resonance imaging in surgical planning for stereotactic electroencephalography
Objective:To investigate the feasibility and accuracy of high-resolution three-dimensional contrast-enhanced magnetic resonance venography(3D CE-MRV) combined with three-dimensional T1-weighted magnetic resonance imaging(3D T1-weight MRI) in surgical planning for stereotactic electroencephalography. Methods:A total of 12 patients with medically intractable epilepsy who planned to undergo SEEG surgery were enrolled. Individualized MRI was performed,and the iPlan software was used to develop surgi-cal plans. A total of 89 electrodes were implanted,and the results of the surgery were analyzed. Results:The 89 electrodes were successfully implanted,and no postoperative bleeding was observed. Of all patients,2 had insular epilepsy. Conclusion:High-resolu-tion 3D CE-MRV helps to find the avascular trajectory and 3D T1-weight MRI helps to know the structure of brain tissue in the avascular trajectory. Their combination can accurately develop the surgical plan and reduce complications.
关键词
立体定向脑电图对比增强磁共振静脉成像对比增强磁共振成像并发症
Keywords
stereotactic electroencephalographycontrast-enhanced magnetic resonance venographyT1-weighted magnetic resonance imagingcomplication