ASIR-V and 80 kVp in abdominal CT angiography:evaluation of image quality,radiation dose,and iodine intake
返回论文页
|更新时间:2023-12-22
|
ASIR-V and 80 kVp in abdominal CT angiography:evaluation of image quality,radiation dose,and iodine intake
Journal of Chongqing Medical UniversityVol. 44, Issue 10, Pages: 1337(2019)
作者机构:
大连医科大学附属第一医院放射科,大连,116011
作者简介:
基金信息:
DOI:
CLC:
Published:2019,
扫 描 看 全 文
Wei Wei, Liu Yijun, Liu Ailian, et al. ASIR-V and 80 kVp in abdominal CT angiography:evaluation of image quality,radiation dose,and iodine intake. [J]. Journal of Chongqing Medical University 44(10):1337(2019)
DOI:
Wei Wei, Liu Yijun, Liu Ailian, et al. ASIR-V and 80 kVp in abdominal CT angiography:evaluation of image quality,radiation dose,and iodine intake. [J]. Journal of Chongqing Medical University 44(10):1337(2019)DOI:
ASIR-V and 80 kVp in abdominal CT angiography:evaluation of image quality,radiation dose,and iodine intake
Objective:To examine the effects of 80 kVp on radiation dose,iodine intake,and image quality for abdominal computed to-mography angiography(CTA). Methods:Abdominal CTA was performed in 49 patients(20≤BMI≤23) using GE Revolution CT. The patients were divided based on tube voltage into group A(n=27,80 kVp) and group B(n=22,120 kVp). With the exception of kVp,all scanning parameters in the two groups were the same:automatic mA,50% ASIR-V,default NI,1.25 mm thickness,HD mode,Stnd reconstruction,80 mm detector width,and 0.5 s scan time. Iohexol contrast agent(350 mgI/mL) was administered at 300 mgI/kg(4 mL/s) in group A and at 500 mgI/kg(5 mL/s) in group B,and was automatically tracked at a threshold of 220 HU. The mean CT and SD values of the abdominal aorta,abdominal trunk,common hepatic artery,splenic artery,superior mesenteric artery,and erector spinae at those levels were measured. Image quality(volume rendering and maximum intensity projection),contrast-to-noise ratio(CNR) and signal-to-noise(SNR) of the abdominal artery,volume CT dose index(CTDIvol),dose-length product(DLP),and total iodine intake were determined and compared between the two groups using the SPSS software. Results:There was no significant difference in the CTA image score between group A(4.58±0.51;κ=0.915) and group B(4.32±0.58,κ=0.946)(P>0.05). The CT values of the abdominal aorta,common hepatic artery,splenic artery,and superior mesenteric artery were signifi-cantly higher in group A(584.09±63.54 HU,503.22±58.72 HU,486.44±74.47 HU,and 535.23±54.94 HU,respectively) than in group B(407.89±60.78 HU,368.57±45.31 HU,371.88±49.55 HU,and 387.83±55.85 HU,respectively)(all P<0.05). The SNRs and CNRs were also significantly higher in group A than in group B(both P<0.05). Compared with group B,group A had significantly lower CTDIvol(3.34±0.22 mGy vs. 8.78±0.93 mGy;61.96% reduction) and DLP(172.77±13.75 mGy·cm vs. 438.30±58.23 mGy·cm;60.58% reduction). The total iodine intake of each patient was reduced by 39.67% in group A(300 mgI/kg) compared with group B (500 mgI/kg). Conclusion:Abdominal CTA at a low tube voltage of 80 kVp(20 kg/m2≤BMI≤23 kg/m2) significantly reduces the radiation dose and contrast agent intake in patients,and improves CNR and SNR of the abdominal aorta and its major branches.
关键词
80 kVp碘摄入量ASIR-V体质指数腹部血管
Keywords
80 kVpiodine intakeASIR-Vbody mass indexabdominal artery
Safety and feasibility of robot-assisted laparoscopic total hysterectomy versus traditional laparoscopic total hysterectomy in patients with different levels of body mass index
Association between age at menarche and hyperuricemia in middle-aged and elderly women and the mediating effect of body mass index
Association between body mass index and the incidence of type 2 diabetes mellitus
Predictive value of waist-to-height ratio for the diagnosis of metabolic syndrome
Analysis of weight change and its related factors of Parkinson’s disease patients
Related Author
Xiao Lin
Chen Wanli
Wu Jialin
Yi Qianlin
Zhu Mengqiu
Qiu Hongbin
Zhang Huanxiang
Zhang Yiying
Related Institution
Department of Gynecology,The First Affiliated Hospital of Chongqing Medical University
Teaching and Research Section of Epidemiology and Health Statistics, School of Public Health, Jiamusi University
Center for Disease Control and Prevention in Changshou District of Chongqing
Department of Neurology,Yongchuan Hospital of Chongqing Medical University
Department of Medical Examination,the First Affiliated Hospital of Chongqing Medical University