Evaluation on bone regeneration in mouse calvarial defect model using Mimics vs. Micro-CT scanner’s built-in software
返回论文页
|更新时间:2023-12-18
|
Evaluation on bone regeneration in mouse calvarial defect model using Mimics vs. Micro-CT scanner’s built-in software
Journal of Chongqing Medical UniversityVol. 40, Issue 2, Pages: 186-190(2015)
作者机构:
1. 重庆医科大学附属口腔医院修复科,重庆,401147
2. 口腔疾病与生物医学重庆市重点实验室,重庆,401147
作者简介:
基金信息:
DOI:
CLC:
Published:2015,
扫 描 看 全 文
Zhang Yufeng, Wang Lu, Gu Xiangdong, et al. Evaluation on bone regeneration in mouse calvarial defect model using Mimics vs. Micro-CT scanner’s built-in software. [J]. Journal of Chongqing Medical University 40(2):186-190(2015)
DOI:
Zhang Yufeng, Wang Lu, Gu Xiangdong, et al. Evaluation on bone regeneration in mouse calvarial defect model using Mimics vs. Micro-CT scanner’s built-in software. [J]. Journal of Chongqing Medical University 40(2):186-190(2015)DOI:
Evaluation on bone regeneration in mouse calvarial defect model using Mimics vs. Micro-CT scanner’s built-in software
Objective:To compare the results of bone regeneration condition in mouse calvarial defects measured by Mimics or Micro-CT scanner’s built-in software and to evaluate the differences of the two methods. Methods:Defect of 4 mm in diameter was prepared on the right cranium of mice,and in vivo Micro-CT scan was performed immediately after surgery,6 weeks and 12 weeks postopera-tively. Then new bone volume and bone healing rate within the defect were measured after reconstructing 3D images by Micro-CT scanner’s built-in software. The new bone volume and bone healing rate within the defect were quantitatively analyzed using Mimics software. The 2D data of Micro-CT were imported into Mimics software and 3D images were reconstructed by it as well. Results:The bone regeneration volume and bone healing rate at 12 weeks postoperatively were significantly higher than those at 6 weeks postoper-atively,no matter measured by Micro-CT scanner’s built-in software or Mimics software(P<0.05). In addition,there was no signifi-cant difference in the new bone volume and bone healing rate between the results of Mimics software and the results of Micro-CT scanner’s built-in software at 6 weeks and 12 weeks postoperatively(P<0.05). Conclusion:Similar results of new bone regeneration within the calvarial defect are obtained by the two softwares at 6 weeks and 12 weeks postoperatively . However,mimics software is simpler to operate than Micro-CT scanner’s built-in software.
关键词
活体显微CT颅骨缺损Mimics软件骨愈合
Keywords
in vivo Micro-CTcalvarial defectMimics softwarebone regeneration