Micro flow imaging combined with contrast-enhanced ultrasound in the diagnosis of active bleeding from renal trauma: an experimental study
返回论文页
|更新时间:2023-10-11
|
Micro flow imaging combined with contrast-enhanced ultrasound in the diagnosis of active bleeding from renal trauma: an experimental study
Journal of Clinical Ultrasound in MedicineVol. 25, Issue 5, (2023)
作者机构:
解放军总医院第一医学中心超声诊断科
作者简介:
基金信息:
DOI:
CLC:
Published:2023,
Published Online:26 May 2023,
扫 描 看 全 文
Micro flow imaging combined with contrast-enhanced ultrasound in the diagnosis of active bleeding from renal trauma: an experimental study. [J]. Journal of Clinical Ultrasound in Medicine 25(5).(2023)
DOI:
Micro flow imaging combined with contrast-enhanced ultrasound in the diagnosis of active bleeding from renal trauma: an experimental study. [J]. Journal of Clinical Ultrasound in Medicine 25(5).(2023)DOI:
Micro flow imaging combined with contrast-enhanced ultrasound in the diagnosis of active bleeding from renal trauma: an experimental study
Objective To explore the application value of micro flow imaging (MFI) combined with contrast-enhanced ultrasound (CEUS) in the diagnosis and localization of active bleeding from renal trauma. Methods The model of renal trauma with active bleeding was established in 10 healthy Bama miniature pigs. B-mode ultrasound
color Doppler flow imaging
CEUS and MFI combined with CEUS were performed successively after the model was established. The accuracy of CEUS and MFI combined with CEUS in the diagnosis and localization of active bleeding from renal trauma were compared. The inner diameter of damaged vessels in renal trauma with active bleeding was measured on MFI combined with CEUS images. Results 18 cases of renal trauma with active bleeding were successfully established in Bama miniature pigs. The accuracy of CEUS and MFI combined CEUS in the diagnosing of active bleeding was 77.78% and 94.44%
respectively
and the difference was not statistically significant (P>0.05). The accuracy of CEUS and MFI combined CEUS in the localization of active bleeding was 55.56% and 94.44%
respectively
and the difference was statistically significant (P<0.05). The inner diameter of damaged vessels in renal trauma with active bleeding on MFI combined with CEUS images was 1.54-2.42 mm. Conclusion MFI combined with CEUS can clearly display the damaged vessels of renal trauma with active bleeding
accurately diagnose active bleeding
and improve the ability to locate active bleeding
providing more diagnostic information for guiding clinical minimally invasive interventional hemostasis and prognosis evaluation.
Research progress in the application of contrast-enhanced ultrasound in lung diseases
Related Author
王勇
王晓娜
周琦
田野
康琦
王丹
杨晓云
Fan jing
Related Institution
Department of Ultrasound,National Cancer Center,National Clinical Research Center for Cancer,Cancer Hospital,Chinese Academy of Medical Sciences and Peking Union Medical College
Ultrasonography Department,Hospital of Shaanxi Normal University,Shaanxi Xi'an
西安交通大学第二附属医院医用超声研究室
Department of Medical Ultrasound,Yiwu Fuyuan Hospital