Diagnostic value of artificial intelligence ultrasonic assisted diagnosis system combined with contrast-enhanced ultrasound in ACR TI-RADS class 4 nodules
返回论文页
|更新时间:2023-10-11
|
Diagnostic value of artificial intelligence ultrasonic assisted diagnosis system combined with contrast-enhanced ultrasound in ACR TI-RADS class 4 nodules
Journal of Clinical Ultrasound in MedicineVol. 25, Issue 2, (2023)
作者机构:
福建医科大学附属泉州市第一医院
作者简介:
基金信息:
DOI:
CLC:
Published:2023,
Published Online:6 March 2023,
扫 描 看 全 文
Diagnostic value of artificial intelligence ultrasonic assisted diagnosis system combined with contrast-enhanced ultrasound in ACR TI-RADS class 4 nodules. [J]. Journal of Clinical Ultrasound in Medicine 25(2).(2023)
DOI:
Diagnostic value of artificial intelligence ultrasonic assisted diagnosis system combined with contrast-enhanced ultrasound in ACR TI-RADS class 4 nodules. [J]. Journal of Clinical Ultrasound in Medicine 25(2).(2023)DOI:
Diagnostic value of artificial intelligence ultrasonic assisted diagnosis system combined with contrast-enhanced ultrasound in ACR TI-RADS class 4 nodules
Objective To analyze the diagnostic value of artificial intelligence ultrasonic assisted diagnosis system (AI-UADS) combined with contrast-enhanced ultrasound (CEU) for American College of Radiology (ACR) Thyroid Imaging Reporting and Data System (TI-RADS) class 4 nodules. Methods A total of 84 patients with ACR TI-RADS class 4 thyroid nodules admitted to the hospital were enrolled between March 2018 and March 2022. All underwent AI-UADS and CEU examinations. The diagnostic value of the two methods and combined detection for benign and malignant ACR TI-RADS class 4 nodules was compared. Results There were 92 nodules in the 84 patients
including 17 malignant nodules (18.48%). CEU showed that there were 14 malignant nodules
its sensitivity
specificity
accuracy
positive predictive value
negative predictive value and kappa value in the diagnosis of malignant nodules were 82.35%
81.33%
81.52%
50.00%
95.31% and 0.509
respectively. AI-UADS showed that there were 15 malignant nodules
and its sensitivity
specificity
accuracy
positive predictive value
negative predictive value and kappa value were 88.24%
82.67%
83.70%
53.57%
96.88% and 0.567
respectively. The sensitivity
specificity
accuracy
positive predictive value
negative predictive value and kappa value of combined detection were 82.35%
93.33%
91.30%
73.68%
95.89% and 0.724
respectively. The specificity of combined detection was higher than that of CEU and AI-UADS (χ2=0.027
0.044
P<0.05). Conclusion Both AI-UADS and CEU have good diagnostic efficiency for benign and malignant ACR TI-RADS class 4 thyroid nodules
and the combined detection can effectively improve clinical specificity.
关键词
人工智能超声智能辅助系统超声造影甲状腺影像报告和数据系统甲状腺结节诊断价值
Keywords
Artificial intelligence ultrasonic assisted diagnosis systemContrast-enhanced ultrasoundThyroid imaging reporting and data systemThyroid noduleDiagnostic value
Diagnostic Value of Nomogram Model Constructed by Contrast-enhanced Ultrasound Combined with ROMA Index in Epithelial Ovarian Cancer
Diagnostic value of contrast-enhanced ultrasound combined with Lemur-tyrosine kinase 3 in papillary thyroid carcinoma and cervical lymph node metastasis
Value Of Contrast-Enhanced Ultrasound Combined With C-TIRADS Classification In The Differential Diagnosis Of Thyroid Nodules
Evaluation on angiogenesis of esophageal transplanted tumor in nude mice by contrast-enhanced ultrasound time-intensity curves
The application value of contrast-enhanced ultrasound in predicting early therapeutic effect of concurrent chemoradiotherapy for locally advanced cervical cancer