Application of PDCA cycle in carotid ultrasound screening of stroke high-risk population in primary hospital
返回论文页
|更新时间:2023-10-11
|
Application of PDCA cycle in carotid ultrasound screening of stroke high-risk population in primary hospital
Journal of Clinical Ultrasound in MedicineVol. 25, Issue 1, Pages: 70-73(2023)
作者机构:
1. 黄石市中医医院超声影像科
2. 鄂东医疗集团黄石市中心医院湖北理工学院附属医院)超声影像科
3. 鄂东医疗集团黄石市中心医院(湖北理工学院附属医院)超声影像科
作者简介:
基金信息:
DOI:
CLC:
Published:2023,
Published Online:31 January 2023,
扫 描 看 全 文
Application of PDCA cycle in carotid ultrasound screening of stroke high-risk population in primary hospital. [J]. Journal of Clinical Ultrasound in Medicine 25(1):70-73(2023)
DOI:
Application of PDCA cycle in carotid ultrasound screening of stroke high-risk population in primary hospital. [J]. Journal of Clinical Ultrasound in Medicine 25(1):70-73(2023)DOI:
Application of PDCA cycle in carotid ultrasound screening of stroke high-risk population in primary hospital
Objective To explore the application effect of PDCA cycle in improving the quality of carotid ultrasound screening in high-risk population of stroke. Method According to PDCA cycle
50 carotid ultrasound images and reports in the ultrasound picture archiving and communication systems from July 2020 to April 2021 were randomly selected and scored according to the quality scoring standard;The goal of this time is to report more than 95% of class a images
Propose solutions to the problems existing in the image report.Formulate countermeasures from May to June 2021.From July 2021 to April 2022
50 carotid ultrasound images and reports after the implementation of various improvement measures were selected for scoring
Compare the differences of ultrasound image report score and clinical satisfaction between 2021 and 2020.Analyze the changes of carotid ultrasound image report and clinical satisfaction score before and after PDCA cycle
Through training and learning
discussion in the Department and collection of clinical feedback
the carotid ultrasound examination process is continuously optimized. Result Before implementing the PDCA process of standardized medical quality management
The report of class a image of carotid ultrasound accounted for 58% (29 / 50)
and the class a image reached 82% (39 / 50) after implementation;The score of ultrasound image report increased from (87.46 ± 5.87) to (92.74 ± 3.57);Clinical satisfaction increased from (84.46 ± 6.48) to (93.06 ± 3.96) before implementation
The difference was statistically significant (P < 0.05). Conclusion PDCA cycle can effectively improve the image quality
report score and clinical satisfaction of carotid ultrasound screening. It can be applied to other single disease germplasm control in ultrasound department
so as to improve the medical quality of ultrasound department.