Predictive value of optic nerve sheath diameter of ultrasound quantification and plaque characteristics for adverse events in ischemic stroke
返回论文页
|更新时间:2023-10-11
|
Predictive value of optic nerve sheath diameter of ultrasound quantification and plaque characteristics for adverse events in ischemic stroke
Journal of Clinical Ultrasound in MedicineVol. 25, Issue 6, (2023)
作者机构:
重庆市黔江区中医院
作者简介:
基金信息:
DOI:
CLC:
Published:2023,
Published Online:30 June 2023,
扫 描 看 全 文
zhaoyujun. Predictive value of optic nerve sheath diameter of ultrasound quantification and plaque characteristics for adverse events in ischemic stroke. [J]. Journal of Clinical Ultrasound in Medicine 25(6).(2023)
DOI:
zhaoyujun. Predictive value of optic nerve sheath diameter of ultrasound quantification and plaque characteristics for adverse events in ischemic stroke. [J]. Journal of Clinical Ultrasound in Medicine 25(6).(2023)DOI:
Predictive value of optic nerve sheath diameter of ultrasound quantification and plaque characteristics for adverse events in ischemic stroke
Objective: To explore the predictive value of optic nerve sheath diameter (ONSD) of ultrasound quantification and plaque characteristics for adverse events in ischemic stroke. Methods: A total of 38 patients with ischemic stroke admitted to the hospital were enrolled between December 2021 and October 2022. All were given endovascular treatment
and general data of patients were recorded. According to presence or absence of adverse events after treatment
they were divided into adverse event group (8 cases) and control group (30 cases). Results: ONSD
eccentricity index
plaque area
plaque length and enhancement amplitude in adverse event group were significantly higher than those in control group (P<0.05). The results of Logistic regression analysis showed that ONSD
eccentricity index
plaque area
plaque length and enhancement amplitude were independent influencing factors of prognosis (P<0.05). In single detection
AUC of plaque length for predicting prognosis was the greatest. Taking 5.47 as the cut-off value
its sensitivity and specificity were 100.00% and 96.67%
respectively. AUC of plaque length was significantly greater than that of plaque area (P<0.05)
and AUC of plaque length was significantly greater than that of enhancement amplitude (P<0.05). Conclusion: ONSD and plaque characteristics have good predictive value for adverse events in patients with ischemic stroke after intravascular treatment.
Clinical value of optic nerve sheath diameter by ultrasonic detection in the diagnosis and treatment of patients with acute increased intracranial pressure
Application value of ultrasoundmeasuredoptic nerve sheath diameter combined with flash visual evoked potential in evaluating intracranial pressure of patients with craniocerebral injury
Effects of ultrasound-guided thermal ablation on prognosis in patients with advanced colon adenocarcinoma and colorectal liver metastasis
Clinical Application of Two-Dimensional Ultrasound Combined with Three-Dimensional Ultrasound in the diagnosis of Cord-like Structures in Gravid Uterus
Application value of diaphragmatic ultrasonography in respiratory function assessment of premature infants