Evaluation value of three-dimensional ultrasound free anatomy imaging technique and tomographic ultrasound imaging technique for intrauterine adhesions
返回论文页
|更新时间:2023-10-11
|
Evaluation value of three-dimensional ultrasound free anatomy imaging technique and tomographic ultrasound imaging technique for intrauterine adhesions
Journal of Clinical Ultrasound in MedicineVol. 25, Issue 6, (2023)
作者机构:
1. 温州市中西医结合医院妇科
2. 温州市中西医结合医院超声科
作者简介:
基金信息:
DOI:
CLC:
Published:2023,
Published Online:30 June 2023,
扫 描 看 全 文
Evaluation value of three-dimensional ultrasound free anatomy imaging technique and tomographic ultrasound imaging technique for intrauterine adhesions. [J]. Journal of Clinical Ultrasound in Medicine 25(6).(2023)
DOI:
Evaluation value of three-dimensional ultrasound free anatomy imaging technique and tomographic ultrasound imaging technique for intrauterine adhesions. [J]. Journal of Clinical Ultrasound in Medicine 25(6).(2023)DOI:
Evaluation value of three-dimensional ultrasound free anatomy imaging technique and tomographic ultrasound imaging technique for intrauterine adhesions
Objective: To analyze the value of three-dimensional ultrasound free anatomy imaging (OmniView) and tomographic ultrasound imaging (TUI) in evaluating intrauterine adhesions (IUA). Methods: A total of 112 patients with suspected IUA admitted to our hospital from March 2021 to March 2022 were selected
and all underwent OmniView and TUI scans. All patients were treated in our hospital. Taking the results of hysteroscopy as the gold standard
the detection performance of OmniView and TUI for IUA and its classification was analyzed. The receiver operating characteristic curve (ROC) was used to evaluate the performance of OmniView and TUI for IUA. Results: Hysteroscopy detected IUA in 98 cases and non-IUA in 14 cases. Among the adhesion types
62 cases were central type
11 cases were peripheral type
and 25 cases were mixed type. OmniView detected 93 IUA patients and 19 non-IUA patients; 59 central type
10 peripheral type
and 24 mixed type. IUA detected 88 IUA patients and 24 non-IUA patients; 58 central type
7 peripheral type
and 23 mixed type. According to the Kappa consistency test
the results of OmniView
TUI and hysteroscopy were generally consistent (Kappa=0.681
0.625)
and the results of combined detection and pathology were better (Kappa=0.813). According to the ROC model
both OmniView and TUI have certain diagnostic efficacy for IUA
and the combined detection efficacy is the highest. Conclusion: Both OmniView and TUI can be used to detect IUA and its classification. The combined detection of the two has the highest efficiency
and the combined detection results are in good agreement with the results of hysteroscopy