To study the ultrasonographic manifestations of lung lesions in silicosis rat model
To investigate the feasibility of ultrasonic examination in silicosis rat model.method Seventeen SPF SD rats were selected
and 1ml sterile silica dust suspension was injected into the trachea of the rats by non-exposure dust contamination method to establish silicosis rat model.Dye dust before
All rats were examined by lung ultrasound
Ultrasound findings of lung were recorded (Pleural line、b lines、 surrounding lung tissue)
And retain the image;Lung HRCT was performed
images were retained
and lung conditions were observed. One month after dust exposure
all rats were examined by lung ultrasound and HRCT with the same method. Then the rats were sacrificed and their lung tissues were collected for pathological specimens
which were stained by HE and Masson and observed under light microscope.result Dye dust before
ultrasonic display:The sonogram of all rats showed smooth pleural line with good continuity
no increase of B line and no lesion of peripulmonary tissue;HRCT performance:Image quality is poor and lung texture is blurred.After 1 month of dust exposure
ultrasonic display:Compared with before dust exposure
9 rats (52.94%) had hypoechoic clusters around lung tissue;14 rats (82.35%) showed increased B line;Pleural line thickening was detected in 17 rats (100%)
and the difference was statistically significant before and after dust (P lt; 0.05);14 rats (82.35%) were found to have blurred and irregular pleural lines with discontinuity.HRCT performance:The image quality is poor and the lung texture is blurred.The outline of the large lesion in the lung can be displayed
the details are not clear
and the small lesion is difficult to display.pathology results:Under light microscope
the normal structure of lung tissue in rats was destroyed
alveolar septum was thickened
cellular silicon nodules were formed
fibrous tissue hyperplasia and collagen fiber deposition increased.conclusion Ultrasonographic examination of the lungs of silicosis rats can be found abnormal changes in the pleural line
increased B line
low echoic mass around the lungs and other characteristic sonographic findings
It is concluded that ultrasonography is feasible in silicosis rat model.