Evaluation of ultrasound fibrotouch controlled attenuation parameters in different degrees of fatty liver
返回论文页
|更新时间:2023-10-11
|
Evaluation of ultrasound fibrotouch controlled attenuation parameters in different degrees of fatty liver
Journal of Clinical Ultrasound in MedicineVol. 25, Issue 3, (2023)
作者机构:
1. 重庆市梁平区人民医院超声科
2. 重庆医科大学附属三峡医院超声科
3. 重庆市渝北区中医院超声科
4. 四川省南充市第五人民医院超声科
5. 重庆医科大学附属康复医院超声科
作者简介:
基金信息:
DOI:
CLC:
Published:2023,
Published Online:6 April 2023,
扫 描 看 全 文
Evaluation of ultrasound fibrotouch controlled attenuation parameters in different degrees of fatty liver. [J]. Journal of Clinical Ultrasound in Medicine 25(3).(2023)
DOI:
Evaluation of ultrasound fibrotouch controlled attenuation parameters in different degrees of fatty liver. [J]. Journal of Clinical Ultrasound in Medicine 25(3).(2023)DOI:
Evaluation of ultrasound fibrotouch controlled attenuation parameters in different degrees of fatty liver
Objective: To analyze the value of ultrasound fibrotouch controlled attenuation parameters in the evaluation of different degrees of fatty liver. Methods: From June 2018 to June 2022
120 patients with different degrees of fatty liver were selected as the test group
and 50 healthy volunteers without fatty liver were randomly selected as the control group. Both groups were tested by fibrotouch and liver biopsy. Construct the receiver operating characteristic (ROC) curve
judge the degree of fatty liver disease through the difference of area under the curve (AUC) and fat attenuation parameters
and calculate the sensitivity and specificity. Multiple linear regression analysis is used to establish the regression equation to understand the factors affecting the controlled attenuation parameters. Results: The controlled attenuation parameters of the control group and patients with mild
moderate and severe fatty liver were (198.52 ± 18.54) dB / m
(234.56 ± 17.62) dB / m
(286.97 ± 23.49) dB / M and (342.82 ± 20.55) dB / m
respectively; The AUC of patients with mild
moderate and severe fatty liver were 0.952
0.976 and 0.982 respectively
and the corresponding diagnostic cutoff points were 225 dB / m
256 dB / M and 291 dB / m respectively. The sensitivity and specificity of diagnosing patients with different degrees of fatty liver were more than 85%. The main factors affecting the controlled attenuation parameters were BMI
degree of steatosis
triglyceride
balloon like change
liver hardness
etc.
which had nothing to do with insulin level
alanine aminotransferase
etc. Conclusion: Different degrees of fatty liver can be evaluated by ultrasound fibrotouch controlled attenuation parameters
Effects of ultrasound-guided thermal ablation on prognosis in patients with advanced colon adenocarcinoma and colorectal liver metastasis
Clinical Application of Two-Dimensional Ultrasound Combined with Three-Dimensional Ultrasound in the diagnosis of Cord-like Structures in Gravid Uterus
Application value of diaphragmatic ultrasonography in respiratory function assessment of premature infants
Clinical value of optic nerve sheath diameter by ultrasonic detection in the diagnosis and treatment of patients with acute increased intracranial pressure
To construct a quality evaluation system for facial ultrasound screening in the first trimester