The feasibility study of high frequency ultrasound in evaluating the integrity of female anal sphincter
返回论文页
|更新时间:2023-10-11
|
The feasibility study of high frequency ultrasound in evaluating the integrity of female anal sphincter
Journal of Clinical Ultrasound in MedicineVol. 24, Issue 2, (2022)
作者机构:
1. 上海交通大学附属第六人民医院超声科 上海市超声医学研究所
2. 上海市静安区闸北中心医院妇产科
作者简介:
基金信息:
DOI:
CLC:
Published:2022,
Published Online:2 March 2022,
扫 描 看 全 文
The feasibility study of high frequency ultrasound in evaluating the integrity of female anal sphincter. [J]. Journal of Clinical Ultrasound in Medicine 24(2).(2022)
DOI:
The feasibility study of high frequency ultrasound in evaluating the integrity of female anal sphincter. [J]. Journal of Clinical Ultrasound in Medicine 24(2).(2022)DOI:
The feasibility study of high frequency ultrasound in evaluating the integrity of female anal sphincter
Objective Female anal sphincter was developed and evaluated by high-frequency ultrasound to evaluate the feasibility of high-frequency ultrasound in the integrity evaluation of female anal sphincter. Methods Using high-frequency ultrasound to image the anal sphincter of 110 female subjects who underwent pelvic floor ultrasound from January 2020 to March 2021
the subjects’ anal sphincter were scanned continuously from the cross section and the sagittal plane. Two researchers with different experience Independently evaluate the integrity of the anal sphincter image in the case of mutual blindness
record the damage of the anal sphincter and perform statistical analysis. Results 80 subjects were able to perform imaging of the internal and external anal sphincter through the high-frequency linear array probe
which clearly showed the characteristic anatomical structure of each level of the anal canal from the cross-sectional and sagittal planes. Therefore
when abnormal ultrasound performance occurs
the anal sphincter injury can be detected. Through the Kappa consistency test
the evaluation of the integrity of the anal sphincter by high-frequency ultrasound has strong consistency among researchers with different experiences (Kappa=0.888
P<0.05).Conclusion High-frequency ultrasound can realize the evaluation of the integrity of the anal sphincter through clear imaging of each level of the anal canal
and provide a new imaging method for the evaluation of the anal sphincter.
关键词
高频超声肛门括约肌女性完整性
Keywords
high frequency ultrasoundAnal sphincterFemaleIntegrity
Clinical Value of High Frequency Ultrasound Combined with Shear Wave Elastography in the Evaluation of Chest Wall Radiation Dermatitis in Breast Cancer Patients undergoing
Retrospective study of ultrasound in assessing finger dysfunction after tendon repair in hand and twist
Comparative study of transperineal and transvaginal three-dimensional ultrasound in the exoanal ultrasound imaging of female anal sphincter
The value of high frequency ultrasound in the diagnosis of fibrolipomatous hamartoma
Related Author
岳文胜
于粒粒
黄薪儒
王冬
张勇
蒲大容
李殿城
刘菲菲
Related Institution
Department of Ultrasound,Academician Workstation,Ultrasound Laboratory,the Affiliated Hospital of North Sichuan Medical College,Nanchong Key Laboratory of Medical Ultrasound Engineering
The First Affiliated Hospital of Chongqing Medical University
滨州医学院附属医院(现工作在北京大学人民医院)
Shanghai Jiao Tong University Affliated Sixth People’s Hospital