Evaluation of two-dimensional shear wave elastography in the diagnosis of chronic kidney disease
返回论文页
|更新时间:2023-10-11
|
Evaluation of two-dimensional shear wave elastography in the diagnosis of chronic kidney disease
Journal of Clinical Ultrasound in MedicineVol. 24, Issue 2, (2022)
作者机构:
南京医科大学附属南京医院
作者简介:
基金信息:
DOI:
CLC:
Published:2022,
Published Online:2 March 2022,
扫 描 看 全 文
Evaluation of two-dimensional shear wave elastography in the diagnosis of chronic kidney disease. [J]. Journal of Clinical Ultrasound in Medicine 24(2).(2022)
DOI:
Evaluation of two-dimensional shear wave elastography in the diagnosis of chronic kidney disease. [J]. Journal of Clinical Ultrasound in Medicine 24(2).(2022)DOI:
Evaluation of two-dimensional shear wave elastography in the diagnosis of chronic kidney disease
Abstract: Objective To investigate the diagnostic value of 2D shear wave elastography (2D-SWE) in chronic kidney disease (CKD) and its influencing factors. Methods Renal shearwavevelocity (SWV)
pixel intensity and interlobar artery resistance index (RI) were measured in 114 CKD patients and 31 healthy subjects.CKD patients were divided into stage 1 to 5 groups according to K/DOQI grading standard. The differences of three ultrasonic parameters in different groups of CKD were analyzed and compared with those in healthy subjects.The ROC curve was drawn to compare the performance of each technique in the diagnosis of CKD.Results The SWV of CKD patients were lower than that of healthy subjects
and the pixel intensity and RI of renal interlobar artery were higher than those of healthy subjects (all P<0.05)
and SWV decreased gradually with the increase of CKD stage
while pixel intensity and interlobar RI increased continuously.The differences of the three parameters among different groups were statistically significant (all P <0.001).In the diagnosis of patients with early CKD
2D-SWE was significant (P<0.001). The diagnostic sensitivity of left cortical SWV was up to 81.8% when it was less than 1.13m/s
and the specificity of right cortical SWV was up to 90.0% when it was less than 1.16m/s.Moreover
the AUC area of 2D-SWE was larger than that of pixel intensity and interlobar artery RI (both P <0.05)
and there was no diagnostic difference between interlobar artery RI and pixel intensity (P>0.05).In the diagnosis of patients with advanced CKD
2D-SWE
pixel intensity and interlobar artery RI were all of diagnostic significance (all P <0.001)
and the curve area of 2D-SWE and pixel intensity was greater than that of interlobar artery RI (all P <0.05)
but there was no diagnostic difference between 2D-SWE and pixel intensity (all P >0.05). Stepwise regression analysis showed that systolic blood pressure
RI
pixel intensity and β2 microglobulin were the influencing factors of SWV decrease.Conclusions 2D-SWE
ultrasound histogram and interlobular artery RI have certain diagnostic value for CKD
but 2D-SWE is superior to ultrasound histogram and interlobular artery RI in the diagnosis of early CKD patients. It may be an early diagnosis of CKD
Dynamic monitoring of disease progression
evaluation of curative effect and prognosis provide new methods.
关键词
慢性肾脏病二维剪切波弹性成像超声直方图叶间动脉阻力指数
Keywords
Chronic kidney diseaseTwo-dimensional shear wave elastographygrayscale histogramInterlobar arterial resistance index