Preliminary Research of Shear Wave Elastography inRadiation-induced Brachial Plexopathy of Breast cancer
返回论文页
|更新时间:2023-10-11
|
Preliminary Research of Shear Wave Elastography inRadiation-induced Brachial Plexopathy of Breast cancer
Journal of Clinical Ultrasound in MedicineVol. 23, Issue 7, (2021)
作者机构:
兰州大学第二医院
作者简介:
基金信息:
DOI:
CLC:
Published:2021,
Published Online:26 July 2021,
扫 描 看 全 文
Preliminary Research of Shear Wave Elastography inRadiation-induced Brachial Plexopathy of Breast cancer. [J]. Journal of Clinical Ultrasound in Medicine 23(7).(2021)
DOI:
Preliminary Research of Shear Wave Elastography inRadiation-induced Brachial Plexopathy of Breast cancer. [J]. Journal of Clinical Ultrasound in Medicine 23(7).(2021)DOI:
Preliminary Research of Shear Wave Elastography inRadiation-induced Brachial Plexopathy of Breast cancer
Purpose To explore the diagnostic value of shear wave elastography in radiation brachial plexus neuropathy in patients with breast cancer
and to analyze the correlation between follow-up time after radiotherapy
brachial plexus radiation volume
radiation dose and brachial plexus elastic modulus and shear wave velocity. Methods According to the LENT-SOMA scale
84 patients with breast cancer were divided into group A (grade 1,n=45)
group B (grade 2,n=34) and group C (grade 3,n=5)
and 40 healthy women in the same period were selected as control group. The differences of thickness
perimeter and cross-sectional area of brachial plexus among groups were compared.The elastic modulus and shear wave velocity of brachial plexus weremeasured by SWE technique
and the ROC curve was drawn.The follow-up time after radiotherapy
brachial plexus radiation volume and radiation dose of breast cancer patients were recorded. Results There was no significant difference in the thickness of brachial plexus among the four groups
so were the difference in the perimeter and cross-sectional are between group A and control group
group B and group C(P>0.05)
but the perimeter and cross-sectional area of brachial plexus in group B and group C were significantly higher than those in group A and control group (P<0.05)
the difference was statistically significant.There were significant differences in brachial plexus elastic modulus and SWV among different groups.The values ofelastic modulus and SWV of brachial plexus in group B and C were significantly higher than those in group A
and the values of elastic modulus and SWV in group C were significantly higher than those in group B (P<0.05). The results of correlation analysis showed that the follow-up time
brachial plexus radiation volume and dose in group A
B and C were positively correlated with brachial plexus elastic modulus (r = 0.333
0.414
0.465,P<0.05) and SWV (r = 0.345
0.421
0.482 P<0.05). Conclusion SWE technique can quantitatively evaluate the changes of brachial plexus elasticity and provideimaging reference for early detection and early diagnosis of RIBP.
Clinical Value of High Frequency Ultrasound Combined with Shear Wave Elastography in the Evaluation of Chest Wall Radiation Dermatitis in Breast Cancer Patients undergoing
Differences in ultrasound BI-RADS grading, VTIQ technical parameter and CA153 in patients with breast cancer of different pathological characteristics
A meta-analysis of ultrasonography combined with aspiration biopsy for the diagnosis of anterior lymph nodes in breast cancer
Comparison of ultrasonic imaging characteristics in breast cancer patients with different molecular subtypes
Analysis of the value of angio planewave ultrasensitive imaging and real-time shear wave elastography for the diagnosis of breast cancer
Related Author
黄薪儒
于粒粒
岳文胜
孙章秀
麦湘湘
张亚庆
刘小蓝
彭玉兰
Related Institution
Department of Ultrasound,Academician Workstation,Ultrasound Laboratory,the Affiliated Hospital of North Sichuan Medical College,Nanchong Key Laboratory of Medical Ultrasound Engineering