Diagnostic value of elastic heterogeneity analysis based on SWE technology in correcting BI-RADS category of breast leisions
返回论文页
|更新时间:2023-10-09
|
Diagnostic value of elastic heterogeneity analysis based on SWE technology in correcting BI-RADS category of breast leisions
Journal of Clinical Ultrasound in MedicineVol. 23, Issue 11, (2021)
作者机构:
1. 山西医科大学
2. 山西医科大学第一医院
作者简介:
基金信息:
DOI:
CLC:
Published:2021,
Published Online:29 November 2021,
扫 描 看 全 文
Diagnostic value of elastic heterogeneity analysis based on SWE technology in correcting BI-RADS category of breast leisions. [J]. Journal of Clinical Ultrasound in Medicine 23(11).(2021)
DOI:
Diagnostic value of elastic heterogeneity analysis based on SWE technology in correcting BI-RADS category of breast leisions. [J]. Journal of Clinical Ultrasound in Medicine 23(11).(2021)DOI:
Diagnostic value of elastic heterogeneity analysis based on SWE technology in correcting BI-RADS category of breast leisions
Abstract Objective To explore the application value of elastic heterogeneity analysis based on SWE technology in correcting BI-RADS category of breast leisions. Methods 132 female patients with 135 breast masses were enrolled in this study.All masses were assessed by conventional ultrasound and 2D SWE.The results of BI-RADS classiffication and elastic parameters of leisions were obtained
the Stiffness Gradient(SG) was caculated.Based on the pathological results
the diagnostic efficacy of BI-RADS classiffication and the BI-RADS classiffication adjusted by SG in identifying breast leisions were assessed according to ROC curves.Results In 135 breast masses
There were 75 benign cases and 60 malignant cases.The elastic parameters of malignant leisions were higher than those of benign leisions(P<0.001),the SG has the largest area under the curve(0.925)compared with other elastic parameters.Using 120.2kPa as a threshold for SG
the diagnostic sensitivity
specificity and accuracy of SG in discriminating the benign and malignant breast leisions were 88.3%
96.0%
92.6%.Taking BI-RADS 4b as the diagnostic cut-off point
the AUC value
sensitivity
specificity and accuracy of BI-RADS category for breast assessment before and after correction by SG were 0.914
0.964;88.3%
90.0%;82.7%
92.0%; 85.2%
91.1%
respectively.Conclusions The elastic heterogeneity quantitative analysis based on SWE technology is a valuable tool in distinguishing benign and malignant breast lesions.The BI-RADS classification adjusted by SG exhibit better discriminatory ability in differential diagnosis of breast leisions assessment than before
which can assist in reducing the unnecessary biopsies of breast leisions.
Research progress of echocardiography in evaluation of myocardial fibrosis
The application value of shear wave elastography in evaluating the treatment effect of testicular epididymitis caused by testicular appendage torsion in children
Conventional ultrasound combined with shear wave elastography to distinguish pleomorphic adenoma from Warthin tumor of parotid: comparative with MRI
Application of transperineal shear wave elastography combined with anterior chamber structure parameters in POP screening for puerperaeundergoing natural delivery
Related Author
周玮珺
杨敏
刘勇
徐平
吴兰英
王颖
肖榕
冷晨蕾
Related Institution
安徽医科大学第一附属医院
南京鼓楼医院
Department of ultrasound,Beijing Shijitan Hospital,Capital Medical University