A comparative study of exercise electrocardiogram and treadmill exercise stress contrast-enhanced ultrasound in the diagnosis of coronary heart disease
返回论文页
|更新时间:2023-10-09
|
A comparative study of exercise electrocardiogram and treadmill exercise stress contrast-enhanced ultrasound in the diagnosis of coronary heart disease
Journal of Clinical Ultrasound in MedicineVol. 23, Issue 10, (2021)
作者机构:
东莞康华医院
作者简介:
基金信息:
DOI:
CLC:
Published:2021,
Published Online:29 October 2021,
扫 描 看 全 文
A comparative study of exercise electrocardiogram and treadmill exercise stress contrast-enhanced ultrasound in the diagnosis of coronary heart disease. [J]. Journal of Clinical Ultrasound in Medicine 23(10).(2021)
DOI:
A comparative study of exercise electrocardiogram and treadmill exercise stress contrast-enhanced ultrasound in the diagnosis of coronary heart disease. [J]. Journal of Clinical Ultrasound in Medicine 23(10).(2021)DOI:
A comparative study of exercise electrocardiogram and treadmill exercise stress contrast-enhanced ultrasound in the diagnosis of coronary heart disease
Objective A comparative research on diagnostic effects of the Exercise electrocardiography(EXECG) and contrast-enhanced ultrasound test for Coronary Artery Disease(CAD) will be carried out. Methods This paper takes 120 patients with coronary heart disease who are presently in stable condition and not taken any coronary stent implantation or coronary artery bypass graft as the research object.These patients are treated in our hospital between January 2018 and December 2019.Coronary angiography(CAG) verifies that at least one of the main branches(including anterior descending branch,circumflex branch,right coronary artery) of the coronary artery has fairly narrow microbores to the extent of more than 50%.Check this by EXECG and treadmill exercise stress contrast-enhanced ultrasound,and use CAG as the gold standard,to evaluate the sensitivity,specificity and accuracy of CAD diagnose by these two different ways. Results The sensitivity,specificity and accuracy of CAD diagnose by EXECG were 58%,83% and 72%,when microbores of at least one of the main branches of the coronary artery were narrower by 50%;when microbores were narrower by 75%,the sensitivity,specificity and accuracy would increase to 63%,89% and 79% respectively The degree of narrowness ≥50% has a significant increase
In the meantime,the statistical difference was revealed with P<0.05;the sensitivity,specificity and accuracy were 77%,92% and 85% when the narrowness was more than 50%,which were higher than those of the EXECG treadmill with statistical difference of P<0.05;when the narrowness was more than 75%,the sensitivity,specificity and accuracy increased to 85%,96% and 91%,which were also higher than those of the EXECG treadmill with statistical difference of P<0.05.Conclusion The sensitivity,specificity and accuracy of the EXECG treadmill exercise in diagnosing ischemia of the coronary heart disease are lower than those of the treadmill exercise stress contrast-enhanced ultrasonography. The Treadmill exercise stress contrast-enhanced ultrasonography has a better diagnostic effect on the coronary heart disease.The higher the degree of the coronary stenosis is,the higher diagnostic sensitivity and accuracy of the Treadmill exercise stress contrast-enhanced ultrasonography will be.
Diagnostic value of layered ultrasound strain parameter combined with leukocyte-associated inflammation indices in coronary heart disease
Quantitative assessment of myocardial work in patients undergoing percutaneous coronary intervention by non-invasive left ventricular pressure-strain loop
Related Author
刘家佳
张璐
张艳
杨梦琪
安景景
邓爱云
ZHANG Pengying
XUE Ting
Related Institution
兰州大学第一临床医学院
兰州大学第一医院
Department of Ultrasound,the Affiliated Lianyungang Hospital of Xuzhou Medical University