The value of contrast-enhanced ultrasound combined with serum AFP and GPC3 in the diagnosis of small nodular liver cancer in early cirrhosis
返回论文页
|更新时间:2023-10-11
|
The value of contrast-enhanced ultrasound combined with serum AFP and GPC3 in the diagnosis of small nodular liver cancer in early cirrhosis
Journal of Clinical Ultrasound in MedicineVol. 23, Issue 9, (2021)
作者机构:
1. 沧州市中心医院超声介入科
2. 河北省沧州市中心医院超声介入科
3. 河北医科大学第三医院超声科,河北,石家庄
作者简介:
基金信息:
DOI:
CLC:
Published:2021,
Published Online:29 September 2021,
扫 描 看 全 文
The value of contrast-enhanced ultrasound combined with serum AFP and GPC3 in the diagnosis of small nodular liver cancer in early cirrhosis. [J]. Journal of Clinical Ultrasound in Medicine 23(9).(2021)
DOI:
The value of contrast-enhanced ultrasound combined with serum AFP and GPC3 in the diagnosis of small nodular liver cancer in early cirrhosis. [J]. Journal of Clinical Ultrasound in Medicine 23(9).(2021)DOI:
The value of contrast-enhanced ultrasound combined with serum AFP and GPC3 in the diagnosis of small nodular liver cancer in early cirrhosis
Objective: To explore the diagnostic value of contrast-enhanced ultrasound (CEUS) combined with serum alpha-fetoprotein (AFP) and glypican 3 (GPC3) for early liver cirrhosis and nodular small liver cancer. Methods:The clinical data of 78 patients with early detection of liver cirrhosis and small nodular lesions were retrospectively analyzed. According to the pathological results
they were divided into small liver cancer group (46 cases) and benign lesion group (32 cases). All patients underwent contrast-enhanced ultrasound
serum AFP
and GPC3 levels before operation. The differences in parameters between the two groups were compared
and the value of the three alone or in combination in the diagnosis of small liver cancer was analyzed.Results: The contrast-enhanced ultrasound characteristics of the small liver cancer group were significantly different from those of the benign lesion group (P<0.05). Most of the small liver cancer group showed "fast in and out" performance
while the benign lesion group showed "slow in and slow out" performance. The levels of serum AFP and GPC3 in the small liver cancer group were significantly higher than those in the benign lesion group (P<0.05). Contrast-enhanced ultrasound combined with serum AFP and GPC3 levels in the diagnosis of HCC had the highest accuracy
sensitivity
specificity
positive predictive value
and negative predictive value (P<0.05). Conclusion: Contrast-enhanced ultrasound combined with serum AFP and GPC3 can help improve the differential diagnosis value of small nodular liver cancer in early cirrhosis
and has certain guiding significance for the selection of clinical treatment options.
Value of contrast-enhanced ultrasound combined with shear wave elastography in the diagnosis of benign and malignant nodules in liver parenchyma under the background of cirrhosis
Evaluation on angiogenesis of esophageal transplanted tumor in nude mice by contrast-enhanced ultrasound time-intensity curves
The application value of contrast-enhanced ultrasound in predicting early therapeutic effect of concurrent chemoradiotherapy for locally advanced cervical cancer
Renal schwannoma misdiagnosed by contrast-enhanced ultrasound:a case report
Study on the predictive value of contrast-enhanced ultrasonography for high Ki-67 expression in invasive breast cancer
Related Author
Pan Xi
黄浩
谢斌
张玉敏
赵现伟
陈杰能
郭磊
周洪珍
Related Institution
桂林市第二人民医院
黄冈市中心医院 超声医学科
Department of Abdominal Ultrasound, The Affiliated Hospital of Qingdao UniversityDepartment of Ultrasound,Linyi Tumor Hospital