Contrast-enhanced ultrasound in Diagnosis of Benign and Malignant Spleen Lesions:A Meta-analysis
返回论文页
|更新时间:2023-10-09
|
Contrast-enhanced ultrasound in Diagnosis of Benign and Malignant Spleen Lesions:A Meta-analysis
Journal of Clinical Ultrasound in MedicineVol. 22, Issue 12, (2020)
作者机构:
四川大学华西医院
作者简介:
基金信息:
DOI:
CLC:
Published:2020,
Published Online:31 December 2020,
扫 描 看 全 文
Contrast-enhanced ultrasound in Diagnosis of Benign and Malignant Spleen Lesions:A Meta-analysis. [J]. Journal of Clinical Ultrasound in Medicine 22(12).(2020)
DOI:
Contrast-enhanced ultrasound in Diagnosis of Benign and Malignant Spleen Lesions:A Meta-analysis. [J]. Journal of Clinical Ultrasound in Medicine 22(12).(2020)DOI:
Contrast-enhanced ultrasound in Diagnosis of Benign and Malignant Spleen Lesions:A Meta-analysis
[Abstract] Objective The aim of this study is to evaluate the differential diagnostic value of contrast-enhanced ultrasound (CEUS) for benign and malignant spleen lesions. Materials and Methods Clinical research reports of contrast-enhanced ultrasound(CEUS) differential diagnosis of splenic benign and malignant lesions were collected from Google scholar
PubMed
Embase
VIP database
WanFang database
CNKI during the time from establishment to March 10
2020. The two researchers screened the literature and extracted relevant information respectively and use QUADAS tool to evaluate the quality of all the included literatures. The software STATA 15.1 was used for statistical analysis. Results A total of 19 literatures (776patients
875 lesions
515 benign lesions and 360 malignant lesions) were included. The overall sensitivity of CEUS in the differential diagnosis of benign and malignant lesions of spleen was 0.97[95% CI: 0.91
0.99]
the overall specificity was 0.91[95% CI: 0.87
0.93]
the overall positive likelihood ratio was 10.5[95%CI: 7.7
14.4]
the overall negative likelihood ratio was 0.04[95% CI: 0.01
0.10]
the overall diagnosis ratio was 274 [95% CI: 96
781]
and the area under the SROC curve was 0.96[95%CI:0.94
0.97]
the sensitivity Q test P < 0.01
the I2 statistic was 65.63%
indicating the heterogeneity among the studies. The results of symmetry test were P = 0.01 and < 0.05
indicating the existence of publication bias. Conclusion Contrast-enhanced ultrasound (CEUS) is a valuable diagnostic method for benign and malignant lesions of spleen.