Value Of Contrast-Enhanced Ultrasound Combined With C-TIRADS Classification In The Differential Diagnosis Of Thyroid Nodules
返回论文页
|更新时间:2023-10-11
|
Value Of Contrast-Enhanced Ultrasound Combined With C-TIRADS Classification In The Differential Diagnosis Of Thyroid Nodules
Journal of Clinical Ultrasound in MedicineVol. 25, Issue 7, (2023)
作者机构:
Tel:?邮箱:@qqcom
作者简介:
基金信息:
DOI:
CLC:
Published:2023,
Published Online:31 July 2023,
扫 描 看 全 文
FU QIANG. Value Of Contrast-Enhanced Ultrasound Combined With C-TIRADS Classification In The Differential Diagnosis Of Thyroid Nodules. [J]. Journal of Clinical Ultrasound in Medicine 25(7).(2023)
DOI:
FU QIANG. Value Of Contrast-Enhanced Ultrasound Combined With C-TIRADS Classification In The Differential Diagnosis Of Thyroid Nodules. [J]. Journal of Clinical Ultrasound in Medicine 25(7).(2023)DOI:
Value Of Contrast-Enhanced Ultrasound Combined With C-TIRADS Classification In The Differential Diagnosis Of Thyroid Nodules
Objective To evaluate the value of contrast-enhanced ultrasound (CEUS) combined with C-TIRADS classification in the diagnosis of benign and malignant thyroid nodules. Methods A total of 116 patients with 121 thyroid nodules who underwent ultrasound examination and contrast-enhanced ultrasound were selected for C-TIRADS classification and contrast-enhanced ultrasound evaluation
using surgical pathology findings and fine-needle aspiration (FNA) biopsy pathology as the gold standard. Receiver operator characteristic (ROC) curve was used to compare the diagnostic performance of C-TIRADS
CEUS and a combination of both methods. Results ROC curve showed that AUC of C-TIRADS
CEUS and the combination of both methods were 0.820
0.824 and 0.886 respectively. The optimal truncation values in differentiating benign and malignant nodules were 4C
2points and 4C. The area under the ROC of CEUS combined with C-TIRADS classification was higher than those of C-TIRADS classification and CEUS scoring
the difference was statistically significant (Z=3.183,P<0.01;Z=2.070,P=0.038).Conclusion CEUS has revised value for C-TIRADS 4 nodules. CEUS combined with C-TIRADS classification can significantly improve the diagnostic performance of benign and malignant thyroid nodules.
关键词
甲状腺结节超声造影甲状腺影像学报告及数据系统鉴别诊断
Keywords
Thyroid noduleContrast-enhanced ultrasoundthyroid imaging report and data systemDifferential diagnosis
Diagnostic value of artificial intelligence ultrasonic assisted diagnosis system combined with contrast-enhanced ultrasound in ACR TI-RADS class 4 nodules
Study on the differential diagnosis of renal cell carcinoma subtype and angiomyolipoma by contrast-enhanced ultrasound
Clinical value of contrast-enhanced ultrasonography in differential diagnosis of hepatic epithelioid angiomyolipoma and hepatocellular carcinoma
Evaluation on angiogenesis of esophageal transplanted tumor in nude mice by contrast-enhanced ultrasound time-intensity curves
The application value of contrast-enhanced ultrasound in predicting early therapeutic effect of concurrent chemoradiotherapy for locally advanced cervical cancer
Related Author
林少坤
曾志雄
刘中华
余卫峰
郭旭
樊瑞琪
贾春梅
李廷廷
Related Institution
福建医科大学附属泉州市第一医院
Department of Ultrasound,First Hospital of Shanxi Medical University
Department of Ultrasound,Third Affiliated Hospital of Chongqing Medical University Jieer Hospital