Value of velocity matching and shear wave viscoelasticity in differentiating primary liver cancer from hepatic hemangioma
Journal of Clinical Ultrasound in MedicineVol. 24, Issue 6, (2022)
作者机构:
联勤保障部队第九〇九医院厦门大学附属东南医院)超声医学科
作者简介:
基金信息:
DOI:
CLC:
Published:2022,
Published Online:5 July 2022,
扫 描 看 全 文
Value of velocity matching and shear wave viscoelasticity in differentiating primary liver cancer from hepatic hemangioma. [J]. Journal of Clinical Ultrasound in Medicine 24(6).(2022)
DOI:
Value of velocity matching and shear wave viscoelasticity in differentiating primary liver cancer from hepatic hemangioma. [J]. Journal of Clinical Ultrasound in Medicine 24(6).(2022)DOI:
Value of velocity matching and shear wave viscoelasticity in differentiating primary liver cancer from hepatic hemangioma
: Objective: Explore the value of sound velocity matching technology and ultrasonic shear wave elasticity technology in distinguishing primary liver cancer from liver hemangioma. Methods: A retrospective analysis of 63 patients with hepatic hemangioma (hemangioma group) and 41 patients with primary liver cancer (liver cancer group) selected from February 2019 to August 2020
all underwent ultrasonic shear wave elasticity technology
Sound velocity matching technology detection
compare the ultrasound images of benign and malignant masses as blood flow signal classification
then compare the two groups of patients Vmax
Vmean
ultrasonic shear wave elastography
ZSI
and use ROC curve to analyze the above-mentioned numerical prediction value . Results: The tumors in the liver cancer group were dominated by grade Ⅱ-Ⅲ blood flow signals
the internal echo was uneven
the shape was irregular
the boundary was not clear
and the appearance was hypoechoic; the tumors in the hemangioma group were dominated by grade 0-Ⅰ blood flow signals with morphology Rules
clear boundaries
uniform internal echo. The ultrasound performance and blood flow signal grades detected by SSC technology and SWE technology were not statistically different (P>0.05). The ZSI value
ultrasound shear wave elastography value
Vmax and Vmean values ??of patients in the liver cancer group were higher than those in the hemangioma group ( P<0.05)
ROC curve analysis showed that ZSI value
ultrasonic shear wave elastography value
Vmax
Vmean and the combination of four items predicted AUC of 0.903
0.885
0.905
0.936
0.989 when distinguishing benign and malignant masses
respectively. Conclusion: Sound velocity matching technology and ultrasonic shear wave elasticity technology have certain effectiveness in distinguishing hepatic hemangioma and primary liver cancer
but the combination of the two can better reduce the misdiagnosis rate and provide scientific basis for clinical diagnosis and treatment.