Application of acoustic radiation force impluse imaging technique in differential diagnosis of hysteromyoma degeneration
返回论文页
|更新时间:2023-10-09
|
Application of acoustic radiation force impluse imaging technique in differential diagnosis of hysteromyoma degeneration
Journal of Clinical Ultrasound in MedicineVol. 22, Issue 11, (2020)
作者机构:
1. 浙江大学医学院附属第一医院心血管超声中心
2. 丽水市人民医院超声科
3. 丽水市人民医院妇产科
作者简介:
基金信息:
DOI:
CLC:
Published:2020,
Published Online:1 December 2020,
扫 描 看 全 文
Application of acoustic radiation force impluse imaging technique in differential diagnosis of hysteromyoma degeneration. [J]. Journal of Clinical Ultrasound in Medicine 22(11).(2020)
DOI:
Application of acoustic radiation force impluse imaging technique in differential diagnosis of hysteromyoma degeneration. [J]. Journal of Clinical Ultrasound in Medicine 22(11).(2020)DOI:
Application of acoustic radiation force impluse imaging technique in differential diagnosis of hysteromyoma degeneration
Objective To investigate the application of acoustic radiaction force impulse imaging technique(ARFI) in evaluating the differential diagnosis of hysteromyoma degeneration. Methods 115 cases of hysteromyoma confirmed by surgical pathology were divided into two groups: degenerated and undegenerated groups. All were detected by ARFI
which were all recorded and analysed with statistics. Results There was no significant difference in the internal echo of uterine fibroids between the degeneration group and the undenatured group
and the larger diameters were more likely to be degenerated. The stress-type elastic score
area ratio and VTQ of the degeneration group were lower than those of the undenatured group
and the difference was statistically significant (P<0.05).The VTQ level of the degenerated group was lower than the undegenerated group
meanwhile the difference was statistically significant (P<0.05). The area under the ROC curve was 0.72
and the cutoff value was 2.52 m/s. At this present
the sensitivity
specificity and accuracy of hysteromyoma degeneration were 65.52%
79.10% and 88.69 % respectively. The sensitivity
specificity
positive predictive value
negative predictive value and accuracy of ARFI technique combined with stress-type elastography for the assessment of uterine fibroid degeneration were 86.36%
96.59%
70.37%
91.40% and 90.43%
respectively. ARFI technology or in combination with stress elastography can significantly improve diagnostic accuracy. Conclutions ARFI technology can provide quantitative indicators of tissue hardness
and combined with stress-based elastography can significantly improve the diagnostic accuracy and contribute to the differential diagnosis of uterine fibroids.
关键词
声辐射力脉冲成像技术 子宫肌瘤 变性
Keywords
Acoustic radiation force impluse imaging technique,Hysteromyoma,degeneration