YANG Bo. An analysis of the difference in lung dose between two radiotherapy regimens for lung tumor based a phantom. [J]. Journal of Southwest Medical University 44(1):46-50(2021)
YANG Bo. An analysis of the difference in lung dose between two radiotherapy regimens for lung tumor based a phantom. [J]. Journal of Southwest Medical University 44(1):46-50(2021)DOI:
An analysis of the difference in lung dose between two radiotherapy regimens for lung tumor based a phantom
Objective:To compare the percentages of lung volume receiving ≥ 20 Gy(V20) and ≥ 30 Gy(V30) between interstitial brachytherapy(ISBT) and intensity-modulated radiotherapy(IMRT) in advanced lung cancer patients with mediastinal lymph node metastasis
and to investigate the feasibility of using ISBT for the lung tumor plus IMRT for mediastinal lymph nodes to reduce the lung dose. Methods:The target volumes of lung tumor and mediastinal lymph nodes were delineated on the CT images of a human phantom. The ISBT plan and IMRT plan were made for each target volume
and the IMRT plan was made for the mediastinal lymph node target volume. Comparison of lung V20 and V30 was made. The relationship between V20 difference and the size of target volume was analyzed. Results:Lung V20 and V30 were lower in the regimen involving ISBT plan
and there were significant differences in lung V20 and V30 between the two regimens(P < 0.05)
except in lung V20 for the lung target volumes of the same size(P > 0.05). The V20 and V30 differences of the two regimens decreased with the increase in the size of target volume. Conclusion:ISBT for the lung tumor plus IMRT for mediastinal lymph nodes is feasible to reduce the lung dose
Comparison of radiation dose in the supraclavicular region between intensity-modulated radiotherapy and three-dimensional conformal radiotherapy after radical mastectomy