Finite element analysis of biomechanical comparison of cervical hybrid surgery in continuous two-level segments
|更新时间:2026-01-09
|
Finite element analysis of biomechanical comparison of cervical hybrid surgery in continuous two-level segments
Journal of Army Medical UniversityVol. 37, Issue 8, Pages: 809-815(2015)
作者机构:
作者简介:
基金信息:
DOI:
CLC:R318.01;R681.53;R687.4
Published:2015
稿件说明:
移动端阅览
唐北川,任先军,邹喜红.连续两节段颈椎hybrid手术的有限元法生物力学对比分析[J].陆军军医大学学报(原第三军医大学学报),2015,37(08 ):809-815. Tang Beichuan,Ren Xianjun,Zou Xihong.Finite element analysis of biomechanical comparison of cervical hybrid surgery in continuous two-level segments[J].J Amry Med Univ (J Third Mil Med Univ),2015,37(08 ):809-815.
唐北川, 任先军, 邹喜红. Finite element analysis of biomechanical comparison of cervical hybrid surgery in continuous two-level segments[J]. Journal of Army Medical University, 2015, 37(8): 809-815.
唐北川,任先军,邹喜红.连续两节段颈椎hybrid手术的有限元法生物力学对比分析[J].陆军军医大学学报(原第三军医大学学报),2015,37(08 ):809-815. Tang Beichuan,Ren Xianjun,Zou Xihong.Finite element analysis of biomechanical comparison of cervical hybrid surgery in continuous two-level segments[J].J Amry Med Univ (J Third Mil Med Univ),2015,37(08 ):809-815.DOI:
唐北川, 任先军, 邹喜红. Finite element analysis of biomechanical comparison of cervical hybrid surgery in continuous two-level segments[J]. Journal of Army Medical University, 2015, 37(8): 809-815.DOI:
Finite element analysis of biomechanical comparison of cervical hybrid surgery in continuous two-level segments
Objective To comparatively analyze biomechanical characteristics of cervical hybrid surgery (artificial cervical disc replacement combined with segmental fusion) in continuous two-level with finite element method. Methods C2~T1 finite element model was established to simulate arthroplasty by Prestige-LP prosthesis
and arthrodesis by anterior plate/screw/allograft in C3~C5
C4~C6 and C5~C7 segments. The difference and change trend of range of motion (ROM) and stress of facet joint (Von Mises stress
Mises stress) of corresponding hybrid surgery were compared. Results (1) With C3~C5 hybrid surgery
the ROM of C3~C4 segments was increased by 119%
186%
208%
and 173% in flexion
extension
axial rotation
and lateral bending
respectively
while that of C4~C5 segments was increased by 142%
262%
251%
and 164%
respectively. The facet Mises stress of C3~C4 segments was increased by 256%
187%
and 185% in extension
axial rotation
and lateral bending
respectively
while that of C4~C5 segments was increased by 50%
54%
and 124%
respectively. (2) With C4~C6 hybrid surgery
the ROM of C4~C5 segments was increased by 107%
200%
238%
and 145% in flexion
extension
axial rotation
and lateral bending
respectively
while that of C5~C6 segments was increased by 65%
130%
147%
and 111%
respectively. The facet Mises stress of C4~C5 segments was increased by 20%
53%
and 111% in extension
axial rotation
and lateral bending
respectively
while that of C5~C6 segments was reduced by 8% in extension
and increased by 297% and 60% in rotation and later bending
respectively. (3) With C5~C7 hybrid surgery
the ROM of C5~C6 segments was increased by 77%
167%
179%
and 122% in flexion
extension
axial rotation
and lateral bending
respectively
and that of C6~C7 segments was increased by 84%
268%
324%
and 230%
respectively. The facet Mises stress of C5~C6 segments was increased by 267% and 63% in axial rotation and lateral bending
respectively; while that of C6~C7 segments was increased by 202%
155%
204%
and 145% in flexion
extension
axial rotation
and lateral bending
respectively. Conclusion The ROM and Mises stress of the replacement segments in the hybrid surgery are increased. The segments with larger ROM are selected for arthroplasty while the segments with smaller ROM are selected for arthrodesis
and the hybrid surgery has less effect on the cervical biomechanics.