Xu Duo,Zhu Xiaoyan,Liu Lina,Chen Xia,Wang Wei,Kan Qiuxia,Xie Lin.Evaluation of central anterior chamber depth before and after laser peripheral iridoplasty in primary angle-closure glaucoma by Pentacam and SL-OCT[J].J Amry Med Univ (J Third Mil Med Univ),2014,36(12):1327-1330.
Xu Duo,Zhu Xiaoyan,Liu Lina,Chen Xia,Wang Wei,Kan Qiuxia,Xie Lin.Evaluation of central anterior chamber depth before and after laser peripheral iridoplasty in primary angle-closure glaucoma by Pentacam and SL-OCT[J].J Amry Med Univ (J Third Mil Med Univ),2014,36(12):1327-1330.DOI:
Evaluation of central anterior chamber depth before and after laser peripheral iridoplasty in primary angle-closure glaucoma by Pentacam and SL-OCT
To evaluate the central anterior chamber depth (CACD) before and after laser peripheral iridoplasty (LPI) in patients with primary angle-closure glaucoma (PACG)
and assess the difference
relevance and consistency between Pentacam and slit-lamp-adapted optical coherence tomography (SL-OCT) in measuring CACD. Methods A total of 58 PACG patients (58 eyes) were enrolled in this study. Pentacam anterior segment analysis system and Heidelberg SL-OCT were used separately before and in 1 d
1 week
and 1 month after LPI to measure the CACD in all patients. Results The mean CACD values of PACG before and in 1 d
1 week
and 1 month after LPI measured by Pentacam were 1.60±0.31
1.65±0.28
1.62±0.30
and 1.61±0.31mm
respectively
while those measured by SL-OCT were 1.70±0.30
1.73±0.30
1.71±0.31
and 1.72±0.31 mm
respectively. Using the 2 methods
no statistical differences was observed in the CACD values before and after LPI in PACG (
P
0.05). Significant differences of CACD values
however
existed between the 2 methods at all time points (
P
0.01). Good correlations were found between Pentacam and SL-OCT before and in 1 d
1 week
and 1 month after LPI (r=0.929
P
0.001; r=0.962
P
0.001; r=0.961
P
0.001; and r=0.951
P
0.001
respectively). By Bland-Altman analysis
the 95% limits of differences between Pentacam and SL-OCT before and in 1 d
1 week
and 1 month after LPI were -0.33 to 0.12
-0.29 to 0.08
-0.25 to 0.08
and -0.26 to 0.07 mm
respectively. Conclusion In PACG
Pentacam and SL-OCT
of good consistency and correlation in measuring CACD
can be both used for glaucoma screening
and provide an effective non-invasive and quantitative way for patients.
Effect of corneal cross-linking surgery on corneal densitometry in patients with keratoconus
Application of active-fluidic pressure control phacoemulsification system for primary angle-closure glaucoma with cataract: reports of 24 cases
Relationship of glutathione S-transferase M1 and T1 polymorphisms with the susceptibility of primary angle-closure glaucoma of Chinese Han population in Chongqing