Evaluation of efficacy of different ablation strategies on cavotricuspid isthmus-dependent atrial flutter
Objective To investigate the efficacy of different ablation strategies
maximum voltage-guided (MVG) ablation
polarity reversal-guided ablation and linear ablation
on patients with cavotricuspid isthmus (CTI)-dependent atrial flutter. Methods Thirty-four patients with typical
atrial flutter were randomly divided into group A
group B and group C. In group A (n=12) continuous linear ablation was performed at CTI. In group B (n=11)
MVG ablation was performed at CTI. In group C (n=11) radiofrequency (RF) ablation guided by reversal of polarity was performed at CTI. In each group
when bidirectional isthmus block was not achieved after the ablation strategies
residual conduction gaps were mapped and eliminated by additional RF application. The following parameters were compared: acute success rate
recurrence rate in long-term follow-up
operation time
X-ray exposure time
number of RF applications
and total RF ablation duration. Results Bidirectional isthmus block was achieved in all patients except for 1 case in group C
without serious complication. There were lower mean number of RF applications (group A
23.2±8.7; group B
13.4±3.6; group C
7.2±3.1;
P
0.01) and shorter total RF duration (group A
15.4±6.8 min; group B
6.7±3.5 min; group C
5.4±2.6 min;
P
0.01) in group B and group C than in group A. Operation time (group A
70.0±45.1 min; group B
50.8±30.5 min; group C
65±38.5 min;
P
0.05) and X-ray exposure time (group A
15.2±7.2 min; group B
10.3±6.5 min; group C
16.3±8 min;
P
0.05) were shorter in group B than in other two groups. No difference was observed in respect of recurrence rate in long-term follow-up (2 in group A vs 1 in group B vs 1 in group C). Conclusion MVG and polarity reversal-guided ablation strategies are associated with fewer RF applications and shorter ablation duration as compared to linear ablation strategy. Furthermore
MVG ablation strategy has shorter operation and X-ray exposure time than reversal-guided ablation strategy.