Wang Yang,Cai Weihua,Wu Jinjin,Tang Hui,Yang Tao,Tang Shuqian.Design and preliminary simulation of a new perfusion bioreactor for tissue-engineered skin based on quasi-static plane flow field[J].J Amry Med Univ (J Third Mil Med Univ),2013,35(07):622-626.
Wang Yang,Cai Weihua,Wu Jinjin,Tang Hui,Yang Tao,Tang Shuqian.Design and preliminary simulation of a new perfusion bioreactor for tissue-engineered skin based on quasi-static plane flow field[J].J Amry Med Univ (J Third Mil Med Univ),2013,35(07):622-626.DOI:
Design and preliminary simulation of a new perfusion bioreactor for tissue-engineered skin based on quasi-static plane flow field
Objective To design and prepare a novel bioreactor based on the idea of the quasi-static plane flow field for perfusion culture in order to meet the requirement for culturing engineered-skin structures (ESS). Methods A commercial software for computational fluid dynamics (CFD) analysis
FLUENT was used to mimic flow field and wall shear stress (WSS) in the new bioreactor. Based on this
a bioreactor with advantages of stack-up
low stress and homogeneous flat flow field was designed. Results The simulation results showed that the maximum WSS on mesh-like support and on the surface of tissue-engineered skin in the growth chamber was less than 3×10
-5
N/cm
2
and the flow field in the
bioreactor was uniform. The new bioreactor remedied some disadvantages in other bioreactors
such as the heterogeneous characteristics of flow
and the excess volume
etc. Our bioreactor met the requirement of gas-liquid interface and low stress for preparation of tissue-engineered skin. Conclusion Our new bioreactor satisfies the demands of quasi-static plane flow
and it may be suitable for culturing and producing the tissue-engineered skin in the future.