Gong Mingfu,Yang Hua,Zou Liguang,Zhang Song,Zhang Dong,Qi Yueyong.Effect of coating materials on MRI signal intensity and relaxivity of magnetic nanoparticles micelles[J].J Amry Med Univ (J Third Mil Med Univ),2013,35(01):5-9.
Gong Mingfu,Yang Hua,Zou Liguang,Zhang Song,Zhang Dong,Qi Yueyong.Effect of coating materials on MRI signal intensity and relaxivity of magnetic nanoparticles micelles[J].J Amry Med Univ (J Third Mil Med Univ),2013,35(01):5-9.DOI:
Effect of coating materials on MRI signal intensity and relaxivity of magnetic nanoparticles micelles
Objective To analyze the effect of coating materials on the magnetic resonance imaging (MRI) signal intensity and relaxivity of magnetic nanoparticles (MNs) micelles. Methods PEG-b-PCL-MnFe
2
O
4
and PEI-b-PCL-MnFe
2
O
4
MNs micelles
which were MnFe
2
O
4
MNs coated with PEG-b-PCL and PEI-b-PCL
respectively
were examined by MRI. The MRI signal intensity of MNs micelles solution with different concentrations was observed
T
1
and T
2
relaxation time were measured
r
1
and r
2
values were calculated
and the effect of coating materials on the relaxivity of MNs micelles was evaluated. Results The MRI intensity of PEG-b-PCL-MnFe
2
O
4
and PEI-b-PCL-MnFe
2
O
4
solutions changed almost identically. With the increase of concentration
the signal intensity decreased in T
2
WI and T
2
*WI
and the signal intensity of PEG-b-PCL-MnFe
2
O
4
solution decreased significantly compared with that of PEI-b-PCL-MnFe
2
O
4
solution. The signal intensity of the two MNs micelles solutions increased firstly
and then decreased in T
1
WI. At the peak signal intensity
the concentrations were 0.2 mmol/L for PEG-b-PCL-MnFe
2
O
4
and 0.4 mmol/L for PEI-b-PCL-MnFe
2
O
4
and the signal intensity of PEG-b-PCL-MnFe
2
O
4
was lower than that of PEI-b-PCL-MnFe
2
O
4
at the same concentration. The r
2
value of PEG-b-PCL-MnFe
2
O
4
and PEI-b-PCL-MnFe
2
O
4
was 186.4 (mmol/L)
-1
·s
-1
and 83.3(mm
ol/L)
-1
·s
-1
and the r
1
value of PEG-b-PCL-MnFe
2
O
4
and PEI-b-PCL-MnFe
2
O
4
was 0.95 (mmol/L)
-1
·s
-1
and 1.09 (mmol/L)
-1
·s
-1
respectively. Conclusion Coating materials affect the MRI signal intensity and relaxivity of MNs micelles significantly.
Prostate cancer T-stage intelligent diagnosis based on MRI images and deep learning
Value of intravoxel incoherent motion diffusion-weighted MR imaging in preoperative glioma grading
Evaluation of water diffusion microenvironment in healthy brain white matter and gliomas using non-Gaussian diffusion MR imaging: a reproducibility study
Progress of advanced magnetic resonance imaging in evaluation of gliomas
MRI findings of peritumoral edema in convex surface small meningioma and its pathological subtypes