Zheng Qi,Ying Xiaozhang,Shi Shiyuan,Wang Yifan,Liu Yaosheng,Liao Shenghui.Finite element modeling and analysis of complicated lumbar spinal stenosis[J].J Amry Med Univ (J Third Mil Med Univ),2012,34(18):1897-1900.
Zheng Qi,Ying Xiaozhang,Shi Shiyuan,Wang Yifan,Liu Yaosheng,Liao Shenghui.Finite element modeling and analysis of complicated lumbar spinal stenosis[J].J Amry Med Univ (J Third Mil Med Univ),2012,34(18):1897-1900.DOI:
Finite element modeling and analysis of complicated lumbar spinal stenosis
Objective To establish an accurate finite element (FE) model of complete lumbar spine with complicated lumbar spinal stenosis (LSS)
then compare and analyze with normal model. Methods A woman with diagnosed complicated LSS was enrolled in this study after her agreement of informed consent. Her CT scan data were collected. By using specially designed modeling system
a complete FE model of the lumbar with complicated LSS was generated
as well as comparing lumbar model with normal material and geometry. Then
same boundary conditions were applied to do comparison. Results The results demonstrated that the complicated LSS model was stiffer
and its active movement range decreased
by 25.4% compared to normal model. Generally
the stress in the complicated LSS model intended to increase. There were stress concentration around the endplate and disk at the degenerative intervertebral disc L
4
-L
5
and adjacent disc L
3
-L
4
. And the maximum Mises stress of the anulus fibrosus was increased by 129%. Conclusion The lumbar spine with complicated LSS has less range of motion and is stiffer compared to normal model
and there are stress concentration at the degenerative intervertebral disc and adjacent intervertebral disc. The analysis result is useful to practical clinical diagnosis of lumbar spine with LSS.