Wang Yingnan,Fan Xuemei,Zhao Min,Xu Huicheng.Preliminary study on the construction of a tissue-engineered sling with BMSCs and UBM in vitro for treating stress urinary incontinence[J].J Amry Med Univ (J Third Mil Med Univ),2012,34(22):2269-2273.
Wang Yingnan,Fan Xuemei,Zhao Min,Xu Huicheng.Preliminary study on the construction of a tissue-engineered sling with BMSCs and UBM in vitro for treating stress urinary incontinence[J].J Amry Med Univ (J Third Mil Med Univ),2012,34(22):2269-2273.DOI:
Preliminary study on the construction of a tissue-engineered sling with BMSCs and UBM in vitro for treating stress urinary incontinence
Objective To study the possibility of a tissue-engineered sling constructed by using bone marrow mesenchymal stem cells (BMSCs) and urinary bladder matrix (UBM) for therapy the treating stress urinary incontinence (SUI). Methods The BMSCs were isolated
cultured and amplified by combining density gradient centrifugation combined with adhering adherent culture method. The amplified BMSCs were identified by FACS. The UBM was loaded by the third generation of BMSCs for 7 days
and the morphological characteristics of cultured the BMSCs were observed by using light microscopy
and electron microscopy. The biomechanics markers of the stem cell sling including maximum load
Young’s modulus and extensibility stretching were tested by using a universal mechanical tester. The simple UBM
UBM loaded by smooth muscle cells (SMCs) and polypropylene materials were served as controls. Results The isolated and cultured BMSCs were isolated and cultured fusiform
refractive
and proliferative
with adult stem cell characteristics. Flow cytometric analysis showed the cell-surface antigens for on the BMSCs were CD29 (95.3%)
CD45 (1.52%) and CD31 (1.27%). The BMSCs or SMCs loaded on the UBM were able to grow in normally. The stem cell BMSCs sling and the simple UBM showed significant decrease in the maximum load[(0.025±0.003 and 0.018±0.004)kN vs (0.030±0.003 and 0.143±0.0341)kN
P0.01]; and the Young’s modulus significant decreased [(170.820±61.735 and 103.624±52.779) MPa vs (490.730±80.969 and 900.100±192.402)MPa
P0.01] but significant increased in the extensibility stretching [(16.418±1.014 and 22.684±6.848) mm vs (9.498±1.384 and 2.975±0.401) mm
P0.01] as compared with the SMCs sling and polypropylene materials
respectively. Conclusion The rat BMSCs are successfully isolated
and cultured. We successfully built a kind of stem cell sling by culturing BMSCs on UBM. This kind of BMSCs sling and simple UBM showed the greater extensibility compared with the SMCs sling and polypropylene materials.