Chen Lin,Xiao Yingbin,Chen Baicheng,Ma Ruiyan,Cheng Wei,Hao Jia.Urine catheter guided bipolar ablation clamp in surgical treatment of atrial fibrillation associated with valve replacement[J].J Amry Med Univ (J Third Mil Med Univ),2012,34(13):1329-1331.
Chen Lin,Xiao Yingbin,Chen Baicheng,Ma Ruiyan,Cheng Wei,Hao Jia.Urine catheter guided bipolar ablation clamp in surgical treatment of atrial fibrillation associated with valve replacement[J].J Amry Med Univ (J Third Mil Med Univ),2012,34(13):1329-1331.DOI:
Urine catheter guided bipolar ablation clamp in surgical treatment of atrial fibrillation associated with valve replacement
Objectives To investigate a more simple and safe surgical technique for the treatment of atrial fibrillation (AF) with bipolar ablation during the valve replacement. Methods From January 2010 to October 2011
a total of 163 patients were enrolled in this study to investigate the effect of urine catheter-guided bipolar ablation in the surgical treatment of AF
including 55 males and 108 females aged from 27 to 70 years (mean 47.6 years). All the patients had at least 1 year’s history of AF
and the longest one was 15 years. Maximum diameter of the left atrium ranged from 45 to 80 mm
diameter of the left ventricle from 43 to 74 mm and ejection fraction of the left ventricle from 40% to 70%. All the procedures were performed under the cardiopulmonary bypass (CPB). After the start of CPB
the left and right pulmonary veins (PV) were carefully separated and encircled with a urine catheter. With the guidance of the catheter
the bipolar ablation clamps were positioned precisely around the PV. Circle ablation of the right and left PVs was performed
followed by the straight-line ablation between the left inferior and superior PVs and between the left PVs and the opening of the left atrial appendage. Then
the opening of the left atrial appendage was closed with continuous suture
followed by the valve replacement and the ablation of the right atrium. Results This urine catheter-guided bipolar ablation was successfully applied in 163 patients with AF undergoing valve replacement. The surgical process was uneventful in all the patients without any tear of myocardial or vascular tissue and without bleeding events during and after operations. Except for 1 death (0.6%)
all the patients were discharged as expected. Conclusion This technique can effectively simplify the procedure of the ablation of PVs
reduce the associated risk and decrease the incidence of the related complications.