Yang Lihong,Mei Zhechuan,Lu Lin,Sheng Wei,Ji Daoru,Yang Yunping.Oxygen inhalation model during painless gastroscopy[J].J Amry Med Univ (J Third Mil Med Univ),2011,33(17):1865-1867.
Yang Lihong,Mei Zhechuan,Lu Lin,Sheng Wei,Ji Daoru,Yang Yunping.Oxygen inhalation model during painless gastroscopy[J].J Amry Med Univ (J Third Mil Med Univ),2011,33(17):1865-1867.DOI:
Oxygen inhalation model during painless gastroscopy
Objective To study the best oxygen inhalation model during painless gastroscopy. Methods Five hundred and sixty-six patients were randomly divided into non pre-oxygen inhalation group (oxygen was supplied at the time of anesthesia)
2-3 L/min intra-operative oxygen flow group (group Ⅰ)
3-4 L/min intra-operative oxygen flow group (group Ⅲ)
4-5 L/min intra-operative oxygen flow group (group Ⅴ). Respiratory rate and SpO
2
of the patients were recorded before operation
after re-oxygenation
2 min after anesthesia
intra- and post- operation
respectively and pre-oxygen inhalation group (
oxygen-supply begins at 2-3 L/min two minutes before the anethesia): 2-3 L/min intra-operative oxygen flow group (group Ⅱ)
3-4 L/min intra-operative oxygen flow group (group Ⅳ)
4-5 L/min intra-operative oxygen flow group (group Ⅵ). Results The SpO
2
of patients was differently decreased after anesthesia and reached its lowest value 2 min after anesthesia. The SpO
2
was higher in pre-oxygen inhalation group than in non pre-oxygenation group (P0.05). The incidence of hypoxemia was significantly lower in pre-oxygenation group than in non pre-oxygen inhalation group (11/93
8/95 and 10/91 vs 28/98
25/94 and 27/95
P0.05 or P0.01). However,no significant difference was observed in SpO
2
and incidence of hypoxemia in pre-oxygen inhalation group and non pre-oxygenation group receiving oxygen flow at different speeds. Conclusion Oxygen inhalation through a nasal tube at a speed of 2-3 L/min during painless gastroscopy is a safe