Guo Yanli,Wang Haidong,Yang Kang,Wang Wenting,Shen Bin,Guo Aiming.Value of real-time three dimensional transthoracic echocardiography in diagnosing mitral valve prolapse: report of 34 cases[J].J Amry Med Univ (J Third Mil Med Univ),2010,32(12):1332-1335.
Guo Yanli,Wang Haidong,Yang Kang,Wang Wenting,Shen Bin,Guo Aiming.Value of real-time three dimensional transthoracic echocardiography in diagnosing mitral valve prolapse: report of 34 cases[J].J Amry Med Univ (J Third Mil Med Univ),2010,32(12):1332-1335.DOI:
Value of real-time three dimensional transthoracic echocardiography in diagnosing mitral valve prolapse: report of 34 cases
Objective To evaluate the value of real-time three dimensional transthoracic echocardiography in diagnosing mitral valve prolapse. Methods Thirty-four patients with mitral valve prolapse with moderate mitral regurgitation were examined by real-time three dimensional transthoracic echocardiography preoperatively. The categories of mitral pathological change and compartmental localization were judged and recorded
and were compared with surgical findings. Carpentier’s nomenclature was applied to the mitral valve anatomic localization of real-time three dimensional echocardiography and surgery. Three anterior leaflet scallops were defined as A1
A2 and A3
and 3 posterior leaflet scallops were defined as P1
P2 and P3. The surgeons recorded the pathology of mitral valve prolapse
ruptured chordae
and the location of scallop lesions in each leaflet scallop. Results The shape and spatial structure of the anterior and posterior leaflets was clearly displayed using real-time three dimensional transthoracic echocardiography
and the mitral valve and its chordae tendineae were observed through left atrium view and left ventricular view. Compared with surgery findings
the accuracy rate of real-time three dimensional transthoracic echocardiography in diagnosing mitral valve prolapse was 100% qualitatively
94.1%(32/34) in diagnosing the categories of mitral pathological change
and 91.2% (31/34) in localizing the diseased region with the anterior and posterior mitral valve. Conclusion Real-time three dimensional transthoracic echocardiography can clearly display the pathological shape of the mitral valve prolapse
accurately localize the diseased region
and provide reliable evidence to design surgical procedure plans. It has essential value in diagnosing mitral valve prolapse.
Diagnostic value of endoscopic LCPL sign for high-risk intestinal metaplasia in gastric mucosa
Construction of a diagnostic model for chronic mountain sickness among young male migrants to high-altitude areas
Clinical diagnosis and treatment for 3 cases of IgG4-related sinusitis
Fumarate hydratase-deficient renal cell carcinoma in kidney transplant patients: one case report and literature review
Congenital inner ear deformity with spontaneous cerebrospinal fluid leakage: a case series report of 9 children
Related Author
ZHENG Xipeng
PAN Huilin
WU Linyu
HOU Yongying
LIU Qin
MA Qiang
QIN Xiuyuan
LIU Kaijun
Related Institution
Department of Gastroenterology, Chongqing Key Laboratory of Precise Prevention and Treatment of Digestive Malignancies
Department of Pathology, Army Medical Center of PLA/Daping Hospital of Third Military Medical University, Chongqing
First Clinical College of Chongqing Medical University
Department of Medicine and Hygienic Equipment for High Altitude Region, Faculty of High Altitude Military Medicine, Army Medical University (Third Military Medical University)
Department of High Altitude Physiology and Pathology, Faculty of High Altitude Military Medicine, Army Medical University (Third Military Medical University)