Qian Ying,Li Tingting,Wang Jan.CT perfusion imaging in quantitative monitoring for tumour microvascular responses to anti-angiogenesis therapy in rabbits[J].J Amry Med Univ (J Third Mil Med Univ),2010,32(12):1329-1331.
Qian Ying,Li Tingting,Wang Jan.CT perfusion imaging in quantitative monitoring for tumour microvascular responses to anti-angiogenesis therapy in rabbits[J].J Amry Med Univ (J Third Mil Med Univ),2010,32(12):1329-1331.DOI:
CT perfusion imaging in quantitative monitoring for tumour microvascular responses to anti-angiogenesis therapy in rabbits
Objective To investigate the value of CT perfusion imaging in quantitative monitoring on microcirculation hemodynamics
differences between tumor and normal tissues
differences between mass center and edge
and on tumour microvascular responses to anti-angiogenesis therapy. Methods Fifteen male New Zealand white rabbits were established to VX
2
tumor-bearing model. The animals were divided into 2 groups
anti-angiogenesis therapy (n=11
TNP-470
20 to 30 mg/kg)
and control (n=4). DEC-CT scanning (80 kV
120 mA
20 cm VOF) was performed at 1 week after tumor implantation
1 week after anti-angiogenesis therapy
and 2 week after antiangiogenesis therapy. Perfusion parameters
including blood flow (BF)
blood volume (BV)
mean transit time (MTT)
and permeability surface (PS) were calculated for tumor mass
tumor edge
tumor center and normal tissue. Results Significant differences of the average values were observed in BF
PS and MTT between tumor and normal tissue [149.32±30.99 vs 32.18±4.10 ml/(100 g·min)
28.24±5.15 vs 11.88±0.71 ml/(100 g·min)
2.79±0.66 vs 6.57±0.90 s
P0.05
]
. Difference was also seen between tumor edge [175.70±34.43 ml/(100 g·min)
32.43±6.52 ml/(100 g·min)
3.87±0.84 s
]
and tumor center [19.07±3.58 ml/(100 g·min)
18.75±2.10 ml/(100 g·min)
8.11±1.44 s
]
. The significant changes of BF
BV
PS
MTT were observed in the therapy group from 187.57 ml/(100 g·min),5.21 ml/100 g,and 30.74 ml/(100 g·min),3.87s respectively to 118.48 ml/(100 g·min),4.21 ml/100 g,24.02 ml/(100 g·min),and 4.27s in 2 weeks after anti-angiogenesis therapy
but not observed in control group [129.74 ml/(100 g·min),3.22 ml/100 g,25.85 ml/(100 g·min),and 3.68 s vs 362.33 ml/(100 g·min),10.86 ml/100 g,39.31 ml/(100 g·min),and 3.54 s
]
. Conclusion CT perfusion imaging can provide quantitative information on the changes in microcirculation hemodynamics for tumor
and it is a valuable tool for quantitative monitoring on tumour microvascular responses to
Reconstruction of ligament-bone interface by a tissue-engineered cell-tendon complex with characteristics of transitional architecture and its efficacy in rabbits
Development of a rabbit model for benign stricture by partial common bile duct ligation with absorbable surgical suture
Effects of sodium nitrite and isosorbide mononitrate on pulmonary artery pressure and pulmonary vascular remodeling in rats with high pulmonary blood flow pulmonary artery hypertension
Effect of electrical stimulus on sacral nerve on the gut-liver axis in rabbit after acute spinal cord injury