Value of point resolved spectrascopy and stimulated echo acquisition mode of 1H-magnetic resonance in detection of multiple sclerotic foci in brain white matter with normal appearance
|更新时间:2026-01-09
|
Value of point resolved spectrascopy and stimulated echo acquisition mode of 1H-magnetic resonance in detection of multiple sclerotic foci in brain white matter with normal appearance
Journal of Army Medical UniversityVol. 32, Issue 13, Pages: 1408-1412(2010)
Zeng Chun,Li Yongmei,Xie Peng,Lu Fajin,Luo Tianyou,Chen Xuan,Wang Zhongping.Value of point resolved spectrascopy and stimulated echo acquisition mode of 1H-magnetic resonance in detection of multiple sclerotic foci in brain white matter with normal appearance[J].J Amry Med Univ (J Third Mil Med Univ),2010,32(13):1408-1412.
Zeng Chun,Li Yongmei,Xie Peng,Lu Fajin,Luo Tianyou,Chen Xuan,Wang Zhongping.Value of point resolved spectrascopy and stimulated echo acquisition mode of 1H-magnetic resonance in detection of multiple sclerotic foci in brain white matter with normal appearance[J].J Amry Med Univ (J Third Mil Med Univ),2010,32(13):1408-1412.DOI:
Value of point resolved spectrascopy and stimulated echo acquisition mode of 1H-magnetic resonance in detection of multiple sclerotic foci in brain white matter with normal appearance
STEAM)2种2-D氢质子磁共振波谱(proton magnetic resonance spectroscopy
1
H-MRS)在多发性硬化(multiple sclerosis
MS)病灶及看似正常表现脑白质(normal appearing white matter
NAWM)中的价值。 方法 对56例复发-缓解型MS(relapsing-remitting MS
RRMS)患者和25例健康志愿者行常规磁共振成像(conventional magnetic resonance imaging
cMRI)扫描,并采用PRESSS长回波和STEAM短回波
1
H-MRS分析,测定各感兴趣区(region of interest
ROI)代谢物氮-乙酰天门冬氨酸(NAA)、胆碱(Cho)、肌酸(Cr)、脂质(Lip)、乳酸(Lac)和肌醇(Ins)的浓度,分析NAA/Cr、Cho/Cr、NAA/Cho、Lac+Lip/Cr和Ins/Cr在病灶和NAWM区中的变化。 结果 ① PRESS长回波显示NAA/Cr、Cho/Cr、NAA/Cho在急性病灶、慢性病灶和对照组相应脑白质(white matter
To study the value of long echo time (TE) point resolved spectroscopy (PRESS) and stimulated echo acquisition mode (STEAM) of
1
H-magnetic resonance in detection of multiple scleroses (MS) in brain white matter with a normal appearance. Methods Conventional magnetic resonance imaging was performed in 56 patients with relapsing-remitting MS (RRMS) and in 25 healthy volunteers. The results were analyzed using the long TE PRESS sequence and short TE STEAM sequence of
1
H- magnetic resonance. Concentrations of metabolic products
including N-acetylaspartic acid (NAA)
choline (Cho)
creatine (Cr)
lipid (Lip)
lactic acid (Lac)
and inositol (Ins)
were measured in each region of interest (ROI). Changes of NAA/Cr
Cho/Cr
Lip+Lac/Cr and Ins/Cr in MS and brain white matter with a normal appearance were analyzed. Results Long TE PRESS sequence showed that the NAA/Cr
Cho/Cr and NAA/Cho were significantly different in white matter with acute and chronic lesions or in white matter with a normal appearance (P0.01). No significant difference in NAA/Cr and NAA/Cho was observed in white matter with acute and chronic lesions (P0.05). Short TE STEAM sequence showed that the NAA/Cr
Cho/Cr and Lac+Lip/Cr were significantly different in white matter with acute lesions or with a normal appearance. Long TE PRESS sequence and short TE STEAM sequence had no significant difference in detecting NAA/Cr and Cho/Cr in MS (P0.05).However
short TE STEAM sequence was advantageous over long TE PRESS sequence in detecting the Lip
Lac and Ins peaks. Conclusion Both long TE PRESS and short TE STEAM sequence can detect abnormal metabolites in MS and in white matter with a normal appearance. However
STEAM can detect more metabolites than long TE PRESS.