Wang Huaqiao,Deng Feng,Zhang Lei,Fan Yubo,Zhang Yi.Determing centre of resistance of maxillary anterior teeth in en masse retraction with micro-implant anchorage: a finite element analysis[J].J Amry Med Univ (J Third Mil Med Univ),2010,32(07):669-671.
Wang Huaqiao,Deng Feng,Zhang Lei,Fan Yubo,Zhang Yi.Determing centre of resistance of maxillary anterior teeth in en masse retraction with micro-implant anchorage: a finite element analysis[J].J Amry Med Univ (J Third Mil Med Univ),2010,32(07):669-671.DOI:
Determing centre of resistance of maxillary anterior teeth in en masse retraction with micro-implant anchorage: a finite element analysis
ABAQUS6.5构建“微种植体支抗-上颌前牙整体内收力系”的三维有限元模型,数值模拟从不同高度平面施以水平向内收载荷,并分别计算上颌中、侧切牙、尖牙的初始位移以及初始旋转角度,从而推算牙齿的阻抗中心位置。 结果 整体内收力作用下上颌前牙段的阻抗中心高度为距离牙槽嵴顶5.1 mm处。在微种植体支抗整体内收上颌前牙力系中,中切牙、侧切牙以及尖牙的旋转中心常数分别为50.26、57.30、132.73 mm
Objective To investigate the centre of resistance of the maxillary anterior teeth and the accompanied initial displacement of teeth in en masse retraction with micro-implant anchorage. Methods A dry skull was scanned with high resolution spiral CT
and the obtained data were used to construct the three dimensional finite element model of “the micro-implant-segmented maxillary anterior teeth en masse retraction” force system. A 2 N horizontal retraction force by micro-implant were added to segmented maxillary teeth in every 2-mm interval from the archwire level and the initial displacement were calculated. Results The centre of resistance was located in the position of 5.1 mm above alveolar ridge. The centre of rotation constants were different among the central incisor
lateral incisor and canine. Conclusion The bodily movement or tipping movement can be easily achieved by altering the horizontal height of the retraction force using the “micro-implant-segmented maxillary anterior teeth en masse retraction” force system.