MRI signaling characteristics of ultra-small superparamagnetic iron oxide and GoldMag
*WI磁共振成像。观察不同浓度USPIO和GoldMag在3种序列中的信号强度变化规律,计算信号强度变化比率,绘制浓度信号强度曲线图。 结果 GoldMag与USPIO的MRI信号变化规律基本一致,随浓度增加,FSE T
1
WI信号强度呈升高趋势,FSE T
2
WI信号强度略有下降,GRE T
2
*WI信号强度明显降低。不同成像序列两种对比剂信号强度比较,在FSE T
1
WI,浓度高于30 μg/ml时信号强度有显著性差异(P0.05);在FSE T
2
WI,浓度为40~90 μg/ml时信号强度有显著性差异 (P0.05);在GRE T
2
*WI,两种对比剂信号强度无显著性差异 (P0.05)。 结论 GoldMag与USPIO常规MRI信号特点变化趋势相似,GoldMag是较理想的MRI分子影像学研究纳米粒对比剂,GRE T
2
*WI为USPIO和GoldMag的最佳成像序列。
Abstract
Objective To analyze the MRI signaling characteristics of ultra-small superparamagnetic iron oxide (USPIO) and GoldMag-Coreshell (GoldMag) at different concentrations and to study the appropriate MR imaging methods. Methods USPIO and GoldMag were diluted with phosphate-buffed solution (PBS) into 47 samples at the concentration
s of 0.5 μg/ml~1 000 μg/ml. MRI was performed at FSE T
1
WI
FSE T
2
WI
and GRE T
2
*WI. Rules of changes in signal intensity of GoldMag and USPIO at different concentrations were observed. The signal intensity change ratio was calculated and concentration-signal intensity curves were plotted. Results The MRI signal intensity of USPIO and GoldMag was almost identical. The MRI signal intensity increased at FSE T
1
WI with the increased concentration
decreased slightly at FSE T
2
WI and significantly at GRE T
2
*WI. A significant difference was found in the MRI signal intensity of the two contrast media (>30 μg/ml
40-90 μg/ml)at FSE T
1
WI and FSE T
2
WI (P<0.05) but not at GRE T
2
*WI (P>0.05). Conclusion The MRI signal intensity of USPIO and GoldMag is almost identical. GoldMag is a rather ideal nanoparticle contrast agent for MRI molecular imaging
and GRE T
2
*WI is the best imaging sequence for USPIO and GoldMag.