XIE Zhao,WU Xue-hui,WANG Xu-quan,MA Shu-zhi,XU Jian-zhong,LI Qi-hong.Minimally invasive percutaneous plate osteosynthesis technique in the treatment of distal tibia fracture[J].J Amry Med Univ (J Third Mil Med Univ),2008,30(08):668-670.
XIE Zhao,WU Xue-hui,WANG Xu-quan,MA Shu-zhi,XU Jian-zhong,LI Qi-hong.Minimally invasive percutaneous plate osteosynthesis technique in the treatment of distal tibia fracture[J].J Amry Med Univ (J Third Mil Med Univ),2008,30(08):668-670.DOI:
Minimally invasive percutaneous plate osteosynthesis technique in the treatment of distal tibia fracture
Objective To determine the results of “biologic fixation” with minimally invasive percutaneous plate osteosynthesis technique (MIPO) using anatomic fracture plate in the treatment of distal tibia fracture. Methods We retrospectively analyzed 19 cases of distal tibia fracture treated during August 2004 and December 2006
including 15 cases of close fracture
14 open fracture and 16 accompanied with fibular fracture. Results All patients obtained bone union in average 5.7 months. During average follow-up of 12 months (range 〖JP3〗6-23 months)
no plate failures or loss of fixation/reduction occurred. Conclusion These results show MIPO using anatomic fracture plate in managing distal tibia fracture can decrease soft tissue problems in fracture healing.