HE Sen,CAO Wen,LI Gang,NIU Fu-teng,GUO Feng,SUN Lei.Short-term clinical outcome of quadriceps sparing total knee arthroplasty[J].J Amry Med Univ (J Third Mil Med Univ),2007,29(23):2283-2285.
HE Sen,CAO Wen,LI Gang,NIU Fu-teng,GUO Feng,SUN Lei.Short-term clinical outcome of quadriceps sparing total knee arthroplasty[J].J Amry Med Univ (J Third Mil Med Univ),2007,29(23):2283-2285.DOI:
Short-term clinical outcome of quadriceps sparing total knee arthroplasty
Objective To investigate the early clinical effectiveness after quadriceps sparing total knee arthroplasty. Methods From September 2005 to December 2006
quadriceps sparing total knee arthroplasty in 25 knees was performed for 20 patients (5 males
6 knees; 15 females
19 knees). The patients aged 59 to 82 years (average 68 years). The diagnosis was osteoarthritis in 18 patients
rheumatoid arthritis in 2. Standard total knee arthroplasty in 25 knees was performed for 22 patients in the same period
as control. Results All the patients were followed up from 4 to 19 months with the average of 12 months. The KSS knee score improved from preoperative (58.0±4.1) to postoperative (93.0±1.2) in QS group. The average length of operative incision was 10 cm (range 9 to 12 cm). The average blood loss was 600 ml. No infections
deep venous embolism of lower limb
fractures
loosening of the prostheses
injury of blood vessels and nerves
or dislocations were found in all patients at the last follow-up. Conclusion By avoiding injury to the quadriceps muscle groups and the extensor mechanism
quadriceps sparing total knee arthroplasty had the advantages of less postoperative pain
less blood loss
and earlier functional recovery in comparison with traditional total knee arthroplasty. The initial clinical result was excellent. The key to successful clinical outcome is optimizing patient selection and paying specific attention to operative details.
Planned prosthesis size in modified 3D printed patient-specific instrumentation-assisted total knee arthroplasty: analysis of consistency with intraoperative size
Effect of 3D printed patient-specific cutting guide on patellar height and joint line position in total knee arthroplasty
Slight varus malalignment has no influence on clinical function in patients with femoral lateral bowing after total knee replacement
Risk factors for knee instability after total knee arthroplasty surgery
Related Author
Bin SUN
Jixiao ZHANG
Liang YUAN
Xiaohua WANG
Ke ZHANG
Jie YAO
Bin YANG
Bin YANG
Related Institution
Department of Orthopedics, Peking University International Hospital
Second Department of Orthopedics, Hengshui Eighth People's Hospital
Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University
Second Department of Orthopedics, Gucheng County Hospital
Department of Orthopedics, Second Affiliated Hospital, Army Medical University (Third Military Medical University)